15. Annual Inspection
JCY-1800/1850 VDR/S-VDR Installation Guide
3.2 Sensor data
No.
1
Date and time data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
2
Ship's position data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
3
Ship speed data (either over-the-ground or through-water) shall be acquired and recorded. Check that
the data is accurately acquired. Check the output equipment and connection interface condition.
4
Ship's heading data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
5
Water depth data from echo sounder shall be acquired and recorded. Check that the data is accurately
acquired. Check the output equipment and connection interface condition.
6
Rudder order data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
7
Actual rudder angle (rudder response) data shall be acquired and recorded. Check that the data is
accurately acquired. Check the output equipment and connection interface condition.
8
Engine order data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
9
Engine order response data shall be acquired and recorded. Check that the data is accurately acquired.
Check the output equipment and connection interface condition.
10
Hull door status data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
[* In case of the RO-RO passenger ship that is obliged to indicate to the bridge.
11
Watertight door status data shall be acquired and recorded. Check that the data is accurately acquired.
Check the output equipment and connection interface condition.
[* In case of the ship that is obliged to indicate to the bridge.]
12
Fire door status data shall be acquired and recorded. Check that the data is accurately acquired. Check
the output equipment and connection interface condition.
[* In case of the ship that is obliged to indicate to the bridge.]
13
Hull stress monitoring data shall be acquired and recorded. Check that the data is accurately acquired.
Check the output equipment and connection interface condition.
[* In case of the ship that is obliged to install by IMO regulation.]
14
Wind direction and speed data shall be acquired and recorded. Check that the data is accurately
acquired. Check the output equipment and connection interface condition.
[* If fitted with wind direction and speed meter (anemometer).]
3.3 Bridge Audio data
No.
1
Audio signals at microphones placed in bridge shall be recorded continuously. And audio signals are
played back. Check the installation positions of the microphones. And check number of the installed
microphone.
3.4 Communication Audio data
No.
1
Audio signals from VHF radiotelephone connected to VDR system shall be recorded continuously.
And VHF audio signals are played back. Check the output equipment. And check number of the
connected VHF radiotelephones.
3.5 RADAR Video data
No.
1
Video signals from selected RADAR/ARPA equipment connected with VDR system shall be recorded
every 15 seconds. And video signals are played back. Check the output equipment.
DOC No. 7ZPJD0387C
Procedure & Specification
Procedure & Specification
Procedure & Specification
Procedure & Specification
180

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jcy-1850

Table of Contents