JRC JCY-1800 Installation Manual page 33

Voyage data recorder
Hide thumbs Also See for JCY-1800:
Table of Contents

Advertisement

2) Current:
c) Communication port
d) Data output interface
(4) Environmental condition:
a) Operating temperature:
b) Temperature and humidity:
c) Vibration:
(5) General specification
a) Power voltage:
b) Power consumption:
c) Size:
d) Mass:
e) Color:
1.10.9. Radar Interface Unit (NWP-46)
(1) Function:
(2) Performance:
a) Basic performance:
b) Communication port
(3) Environmental condition:
a) Operating temperature:
b) Temperature and humidity:
c) Vibration:
(4) General specification
a) Power voltage:
b) Power consumption:
c) Size:
d) Mass:
e) Color:
JCY-1800/1850 VDR/S-VDR Installation Guide
+/-20mA
Same port as dry contact signals
Data type: IEC61162-1
Analog Sentence formatter: XDR
-15°C to +55°C (IEC 60945 protected type)
+40°C, 93%
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
25VA
300(w) x 130(d) x 230(h) mm
2.9kg
N7 semi-gloss
-Option-
The NWP-46 is required when a high resolution (UXGA) radar display is
connected to the VDR/S-VDR.
The NWP-46 is an option unit in order to install a FGB near the radar, because
high resolution RGB signals can not be extended to the VDR/S-VDR,
The Frame Grabber Board (FGB) in the NWP-46 is moved from the Recording
Control Unit.
It is the same as the Radar image input specification of the Recording Control
Unit.
To the NDV-1800/1850 RCU via Ethernet
-15°C to +55°C (IEC 60945 protected type)
+40°C, 93%
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
10VA
255(w) x 160(d) x 72(h) mm
1.5kg
N4 semi-gloss
23
1. Specifications
DOC No. 7ZPJD0387C