Chemical Feed Pump Location; Heater Installation - Pentair AK110 Installation And User Manual

Table of Contents

Advertisement

If unit has not been previously installed, follow the instructions included with the chemical feed pump . Some loads
include power cords already connected to the load and are ready to plug in . If "pigtails" have been ordered with the
Controller simply plug the power cord into the appropriate "pigtail" . If "pigtails" are not installed the power cord from
the pump will need to be modified . The list below provides installation recommendations:
1 .
Mount at least 10 feet from open water .
2 .
Install the pump below the level of the Controller and away from any other equipment or systems .
This is to reduce any damage to other equipment should the pump leak .
3 .
Install close enough to the Controller for the feed pump power cords to reach .
4 .
If "pigtails" are included simply plug in the pumps to the appropriate "pigtail" . If pigtails are not installed,
cut the electric plugs from the feed pumps and strip and ferrule the ends .
5 .
Route the power cords to the Controller through the lower fittings and attach to the appropriate relay
terminals on the relay circuit board . If the wire ends were striped and not ferruled make sure that no frays
of wire are out of the connector as this may lead to a short .
6. Conduit or external plugs can also be used (according to the codes in the local area).
7 .
When installing metal conduit into the Controller, a ground LUG should be used to connect the conduit to
the relay board ground .
The Controller third relay can control a heater, turning it on and off based on the temperature settings you have
programmed in to the Controller . The heater control portion of the Controller can be used to maintain a constant
temperature or maintain a temperature during operating hours . Even though the Controller is a very accurate and
reliable device, for safety, always use the over-temp device on your heater to prevent overheating .
1 .
Always install any heater according to the manufacturer's instructions .
2 .
Mount the Controller at least 10 feet from open water .
3 .
Install close enough to the Controller for the wiring connections to reach .
4 .
DO NOT attempt to power the heater with the Controller controller .
5 .
A heater unit must always be independently powered, either through a separate cord, or through an
external relay like the Acu-Trol HAR1 relay module. (Part# 735000060)
6 .
Always use the over-temp device on the heater to prevent overheating .

Chemical Feed Pump Location

Heater Installation

ACU-TROL
®
AK110 Chemical Controller Installation and User's Guide
13