RANGe
Command Syntax:
where:
<time-range >
Example:
Query Syntax:
Returned ,Format:
Example:
HP 1650B/HP 16518
Programming Reference
The RANGe command specifies the full-screen time in the timing
waveform menu. It is equivalent to ten times the seconds-per-division
setting on the display. The allowable values for IWNGe are from 100 ns
to 10 ks.
The FMNGe query returns the current full-screen time.
:: = real number between 100 ns and 10 ks
OUTPUT XXX;":MACHINEl:TWAVEFORM:RANGE
[:MACHine{l IP}:TWAVeform:RANGe] <time-value>
10 DIM Rg$ [loo]
20 OUTPUT XXX;" :MACHINEl:TWAVEFORM:RANGE?"
30 ENTER XXX;
40 PRINT Rg$
50 END