Drain Quench Kit - Jackson crew series Installation, Operation And Service Manual

Conveyor dishmachines
Table of Contents

Advertisement

INSTALLATION
This kit should only be installed by qualified service personnel to reduce the risk of electric shock, serious injury, or
fire. A plumbing permit and the services of a licensed plumber and electrician might be required in some areas.
Turn off the power supply and place the dishwasher disconnect (if applicable) in the off position. Lockout/tag-out to
prevent the power supply from being turned back on accidentally.
Failure to install this kit within the guidelines might adversely affect safety, performance, component life, and warranty
coverage.
Do NOT pull power for the Drain Quench Assembly from the machine! 120V facility power only!
Tools Required
Pipe Wrench
Adjustable Wrench
5/16" Nut Driver
3/8" Nut Driver or Wrench
Phillips Screwdriver
Pipe Thread Sealant Tape or "Pipe Dope"
Needle-nose Pliers
Instructions
1. Connect Drain Quench Assembly to the machine drain via 1.5" NPT street elbow (04730-206-32-00).
2. Orient assembly as shown below:
19
DRAIN QUENCH KIT INSTRUCTIONS
!
WARNING
07610-003-78-18-N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crew 66Crew 44Crew 44sCrew 66sCrew series