Jackson crew series Installation, Operation And Service Manual page 21

Conveyor dishmachines
Table of Contents

Advertisement

ELECTRICAL REQUIREMENTS
66" with 18 kW Wash Heater
Volts
Phase
208
1
230
1
240
1
208
3
230
3
240
3
460
3
480
3
* Denotes 240 volt heating elements that have been down-rated when 230 volts is applied.
** Denotes 480 volt heating elements that have been down-rated when 460 volts is applied.
66" Steam
Volts
Phase
208
1
230
1
208
3
230
3
460
3
40 °F Rise – 12 kW Booster
Volts
Phase
208
1
230
1
208
3
230
3
460
3
Note: On the 208 volt machines, the rinse heater is actually rated at 17.2 kW.
Blower/Dryer
Volts
Phase
Freq
208
3
230
3
460
3
07610-003-78-18-N
Pre-Wash
Freq
Motor
Amps
60
10.2
60
9.4
60
9.4
60
6.8
60
6.4
60
6.4
60
3.2
60
3.2
Pre-Wash
Freq
Motor
Amps
60
10.2
60
9.4
60
6.8
60
6.4
60
3.2
Rinse
Freq
Heater
Amps
60
57.7
60
47.9
60
33.3
60
27.7
60
13.8
Amps
60
32.2
60
22.9
60
13.4
i
Wash
Drive
Motor
Motor
Amps
Amps
10.0
1.8
10.0
1.8
10.0
1.8
8.6
1.1
8.4
1.1
8.4
1.1
4.2
0.6
4.2
0.6
Wash
Drive
Motor
Motor
Amps
Amps
10.0
1.8
10.0
1.8
8.6
1.1
8.4
1.1
4.2
0.6
70 °F Rise – 18 kW Booster
Volts
208
230
208
230
460
SPECIFICATIONS
Wash
Total
Heater
Load
Amps
86.5
108.5
*71.9
93.1
75.0
96.2
50.0
66.5
*41.5
57.47
43.4
59.3
**20.8
28.8
21.7
29.7
Total
Load
22.0
21.2
16.5
15.9
8.0
Phase
Freq
1
60
1
60
3
60
3
60
3
60
Rinse
Heater
Amps
82.7
71.9
47.7
41.5
20.7
12