Drain Quench Kit Option - Jackson Enodis 300X Technical Manual

Upright door dishmachine series
Table of Contents

Advertisement

Elbow, 1-1/2" 90B Street
04730-206-32-00
Nipple, 1-1/2" NPT
04730-207-40-00
Modified Compression
Fitting
05700-001-16-52
Reducer, 1-1/2" x 1/4"
04730-002-55-76
To Dishmachine Drain
Tee, 1-1/2" x 1-1/2" x 1-1/2"
04730-011-69-93
Reducer, 1-1/2" to 1/2"
04730-002-55-75
From the existing drain, attach the two additional Tees using the 1-1/2" NPT Close Nipples. Tighten the Reducers into the Tees
as shown above. Attach the Modified Compression Fitting into the 1-1/2" to 1/4" Reducer. Position the bulb of the thermostat
so that it rests approximately 1/4" from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to
the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.
SECTION 6: PARTS SECTION
DRAIN QUENCH ASSEMBLY
Valve, Check, 1/2"
(Not Shown)
04820-002-55-77
300X Series Technical Manual 7610-002-64-22
Issued: 07-26-2006 Revised: N/A
59
Drain Quench
Assembly
06401-002-59-52
Lid, Drain Quench
05700-002-67-16
Nipple, Close, 1/2" NPT
(Not Shown)
04730-207-15-00
Thermostat
05930-003-13-65
Solenoid Valve
04810-100-09-18
To Cold Water Supply
Box, Drain Quench
05700-002-69-96

Advertisement

Table of Contents
loading

This manual is also suitable for:

300xs300xlt300xn

Table of Contents