WIRING DIAGRAMS

This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.
Star
washer
Nut
Star
washer
Power
cord
ground
ground
wire
Receiver Hearth Mount
RECEIVER
CAUTION: Label all wires
prior to disconnection
when servicing controls.
Wiring errors can cause
improper and dangerous
operation.
(Do not cut the ground terminal off under
any circumstances.)
Lockwasher
Nut
#8 Ground Lug
Fan
WARNING: Electrical Grounding
This appliance is equipped with a
three pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove
the grounding prong from this plug.
120V AC
60 Hz
DC
Spark Box
Instructions
Regency
installation
NOTE:
Even if the fan is not purchased
with the unit, it is still a good idea to
bring power to the receptacle box
(provided with the unit) in case the
fan is installed at a later date.
Ground
Neutral
Live
Green
Ground
Fan Thermodisc
(Normally Open)
Thermodisc Cage
FCM-COM
TH
To
Electrode
(+) (-)
TP
Red
Black
White
TPTH
MOTOR
Thermostat
(Optional)
(Millivolt)
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
U38-10 ULTIMATE Freestanding Gas Stove
®
|
19
Fan
Black
Red
Green
Flue Spill Switch
(Manual Reset)
|
19