This is a copy of the label that accompanies
each ULTIMATE Freestanding Gas Stove. We
have printed a copy of the contents here for your
review. The safety label is located on the inside
of the drop down pedestal door.

SAFETY LABEL FOR THE U38-10

Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certifi ed for/Certifi ée pour: CANADA and U.S.A.
Tested to: CAN/CGA-2.17-M91(R2009)
Conforms to: ANSI Z21.88-2014
Certifi ed to:CSA 2.33-2014
4001172
FACTORY EQUIPPED FOR NATURAL GAS:
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Model U38-NG: Factory Equipped for Altitude 0-2000 ft.
Orifi ce size
Altitude
Maximum Input
Minimum Input
Model U38-NG: Convertible for Altitude 2000-4500 ft.
Orifi ce size
Altitude
Maximum Input
Minimum Input
Model U38-NG: Convertible to 30,000 Btu for Altitude 0-4500 ft.
Orifi ce size
Maximum Input
Minimum Input
FACTORY EQUIPPED FOR PROPANE GAS:
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Orifi ce size
Altitude
Maximum Input
Minimum Input
Model U38-LP: Convertible to 30,000 Btu for Altitude 0-4500 ft.
Orifi ce size
Maximum Input
Minimum Input
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard
is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA
501C Standard for Recreational Vehicles. For use with Fan Kit # 910-331
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, perma-
nently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation
ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping,
ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes,
utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA
501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé
dans une maison préfabriquéo
mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet apparene peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie.
This vented gas fi replace heater is not for use with air fi lters. /Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation
For use with glass doors certifi ed with the appliance only. /Pour utilisation uniquement avec les portes en verre certifi ées avec
l'appareil
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery back up in the same room where the gas appliance is installed.
NOTE: Regency
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Model U38-NG10
ÉQUIPÉ À L'UISINE POUR GAZ NATUREL:
5"
WC/C.E. (1.25kPa)
Pression d'alimentation minimum
3.8"
WC/C.E. (0.94kPa)
Pression tubulure d'échappement élevée
1.1"
WC/C.E. (0.27kPa)
Pression tubulure d'échappement basse
#31
DMS
Dimensions de l'orifi ce
0-2000
ft/pi
(0-610)
L'altitude
40,000
Btu/h
(11.73Kwh)
Débit calorifi que maximum selon
21,000
Btu/h
(6.15Kwh)
Débit calorifi que minimum selon
Transforme en haute l'altitude Gaz Naturel:
#33
DMS
Dimensions de l'orifi ce
2000-4500ft/pi (610-1370m)
L'altitude
36,000
Btu/h
(10.55Kw)
Débit calorifi que maximum selon
19,000
Btu/h
(5.57Kwh)
Débit calorifi que minimum selon
#37
DMS
Dimensions de l'orifi ce
30,000
Btu/h
(8.78Kwh)
Débit calorifi que maximum selon
15,000
Btu/h
(4.39Kwh)
Débit calorifi que minimum selon
Model U38-LP10
ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:
12"
WC/C.E. (3.00Kpa)
Pression d'alimentation minimum
11"
WC/C.E. (2.74Kpa)
Pression tubulure d'échappement élevée
2.9"
WC/C.E. (0.72Kpa)
Pression tubulure d'échappement basse
50
DMS
Dimensions de l'orifi ce
0-2,000 ft/pi
(0-610m)
L'altitude
38,000
BTU/h
(11.14Kw/h)
Débit calorifi que maximum selon
20,000
BTU/h
(5.86Kw/h)
Débit calorifi que minimum selon
#52
DMS
Dimensions de l'orifi ce
30,000
Btu/h
(8.78Kwh)
Débit calorifi que maximum selon
15,000
Btu/h
(4.39Kwh)
Débit calorifi que minimum selon
units are constantly being
®
Duplicate serial #
DO NOT REMOVE THIS LABEL/NE
PAS ENLEVER CETTE ÉTIQUETTE
Degagement minimum des materiaux combustibles:
VENTED GAS FIREPLACE HEATER -
NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE
PAS UTILISER AVEC DU COMBUSTIBLE
SOLIDE.
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:
115V_60HZ less than/moins de 2 AMP
For Use Only with Barrier (Part # 732-512)
Follow installation instructions.
Utiliser uniquement avec l'écran ( n ° 732-512)
Suivre les instructions d'installation.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
.
Made in Canada / Fabrique au Canada
Regency
safety decal
314
314
Serial No./No de serie
Minimum Clearances to Combustibles
A 7-1/2"
/190mm
B 6"
/150mm
E
2"
/50mm
Min. Ceiling Height from top of unit / Min. Plafond
Hauteur en haut de l'appareil:
36" / 914 mm
U38-10 ULTIMATE Freestanding Gas Stove
®
|
5
919-481
|