U38 Top Vent Freestanding B-Vent Gas Stove
Model
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifi ce Size
Altitude 0-2000ft (0-610m)
Orifi ce Size
Altitude 2000-4500ft (610-1370m)
Orifi ce Size
30,000 Max BTU
Minimum Input
Altitude 0-2000ft (0-610m)
Minimum Input
Altitude 2000-4500ft (610-1370m)
Minimum Input
Converted to 30,000 Max BTU
Maximum Input
Altitude 0-2000ft (0-610m)
Maximum Input
Altitude 2000-4500ft (610-1370m)
Maximum Input
Converted to 30,000 Max BTU
Vent Sizing
Approved Venting Systems
Vent Systems:
A
H
G
Dimension
Description
A
Top Width
B
Unit Height
C
Top Depth (back to front face)
D
Top Depth
E
Height; Base to Gas Line
F
Top; Front to Back
G
Depth; Flue-Centerline to Back
H
Width; Side of unit to Gas Line
June 2007 Regency Product Specifi cations Book
Gas Stoves
U38-NG1
U38-LP1
Natural Gas
Propane
5" W.C. (1.25 kPa)
12" W.C. (3.00 kPa)
3.8" W.C. (0.94 kPa)
11" W.C. (2.74 kPa)
1.1" W.C. (0.27 kPa)
2.9" W.C. (0.72 kPa)
#31
#50
#33
#37
#52
21,000 BTU/h
20,000 BTU/h
19,000 BTU/h
15,000 BTU/h
15,000 BTU/h
40,000 BTU/h
38,000 BTU/h
36,000 BTU/h
30,000 BTU/h
30,000 BTU/h
4" B-Vent
4" B-Vent
Listed B-Vent, Class-A or Masonry
Chimney with approved liner (FPI
AstroCap™ Flex Vent)
C
D
B
E
F
U38
26" (660mm)
30" (762mm)
17-5/8" (448mm)
17" (432mm)
3-1/2" (89mm)
17" (432mm)
3-1/2" (89mm)
10-3/4" (273mm)
J
I
N
M
Alcove clearances
Dimension
Description
I
Side Wall to Unit
J
Back Wall to Unit
K
Back Wall to Vent Centerline
L
Side Wall to Vent Centerline
Corner Clearances
Dimension
Description
M
Wall to Unit Corner
N
Wall to Vent Centerline
Minimum ceiling height is 36" (914mm) from top of unit.
Minimum clearance to vent : According to B-Vent Manufacturer
The above listed clearances are minimum distances to combustible
materials. When installing on carpet or vinyl fl ooring the bottom pedestal
cover plate must be installed.
U38 Gas Stove
K
L
I
N
M
U38
7-1/2" (190mm)
6" (155mm)
10-3/4" (273mm)
20-1/2" (521mm)
U38
2" (50mm)
11" (280mm)
155