Quick Links

ULTIMATE U37 Rear Vent
Direct Vent Freestanding Gas Stove
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
918-025a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.regency-fire.com
MODELS:
U37-NG Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
U37-LP Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical
switch: do not use any phone in
your building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Owners &
01/09/06

Advertisement

Table of Contents
loading

Summary of Contents for Regency ULTIMATE U37-LP

  • Page 1 ULTIMATE U37 Rear Vent Owners & Direct Vent Freestanding Gas Stove Installation Manual MODELS: U37-NG Natural Gas U37-LP Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas:...
  • Page 2: Specifications Diagram

    ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove. INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: ANSI Z21.88b- 2003/CSA 2.33b-2003, and CAN/CGA-2.17-M91.
  • Page 3: Table Of Contents

    System Data Chart - U37 ........17 High Elevation ............17 Aeration Adjustment ..........17 Log Installation ............17 Door Installation ............. 19 Gas Pipe Pressure Testing ........19 Valve Description ........... 19 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 4: Safety Label

    For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length. For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 5: Installation

    ING, ETC. IT IS IMPERATIVE THAT must be bolted down to the floor. other reproductive harm. THE CONTROL COMPARTMENT, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 6: Installation Checklist

    3) Appliance must be anchored to the floor installation. If a snorkel termination is required, with the supplied anchoring methods. the Simpson Dura-Vent Direct Vent System Model DVGS terminals are available. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 7: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 8: Venting Installation Precautions

    1-1/4" open. tor must be set at 1-1/8" open. NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 9: Rigid Pipe Venting Components List

    Vent Guard (Optional) - Riser Vent Terminal 640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap 640-994 U37 Rigid Pipe Adaptor 946-206 Vinyl Siding Standoff - AstroCap 946-205 Vinyl Siding Shield for Riser Vent Terminal U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 10: For Both Residential & Manufactured Homes/Mobile Homes

    Vent Restrictor Position To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 11: Venting: Residential And Manufactured

    MOBILE HOMES INSTALLATIONS You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.
  • Page 12 4 extending from the Riser Vent Backing screws. Dia. 4. Plate into the outer wall of the vent pipe. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 13: Vertical Termination With Co-Linear Flex System

    Co-linear Flex Adapter (270-585) Outer Pipe (946-257) Inner Pipe Adapter (946-219) Alternate Approved Caps Vertical Termination Cap High Wind Cap 923GK 3" Co-linear Adapter with flashing U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 14: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    Direct Vent sys- the Retro Connector may be completed Diagram 2. tem within the chimney. with sections of black direct vent pipe, together with an adjustable length. Diagram 2 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 15 Be careful to insure that with an adjustable length pipe section. the connector is centered in the opening and the mounting holes line up with the masonry wall. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 16: Conversion From Natural Gas To Propane

    15) Check operation of flame control. 6) Pull off the pilot cap to expose the pilot 16) Check for proper flame appearance and orifice. glow on logs. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 17: Gas Connection

    Regency Installer at the time of installation or service. This unit is approved in Canada for altitude 0 ft. to 4500 ft. (CAN/CGA-2.17-M91). For Natural Gas installations above 4500 ft. follow current CAN/ CGA-B149.1. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 18 10) Place the notch in Center Log F)02-47 over B)02-56 E)02-45 Log E)02-45 and across the cutout on Log C)02-44 A)02-65. C)02-44 F)02-47 E)02-45 Notch Cutout U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 19: Door Installation

    Note: The door latch may require ad- justment as the door gasket ma- terial compresses after a few fires and after glass replace- ment. Turn the latch catch in- ward or outward. Diagram 3 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 20: Louver Installation

    15 min. to stabilize. CAUTION Any alteration to the product that causes sooting or carboning that results in dam- age to the exterior facia is not the respon- sibility of the manufacturer. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 21: Wiring Diagram

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 22: Operating Instructions

    WITHOUT THE GLASS FRONT IN ing" and "cracking" sounds. You should also be aware that as there are temperature changes PLACE. within the unit these sounds will likely re-occur. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 23: Copy Of The Lighting Plate Instructions

    As the gas control valve turns ON and OFF, a switch contacts closing and is normal. dull clicking sound may be audible, this is normal operation of a gas regulator or valve. COPY OF THE LIGHTING PLATE INSTRUCTIONS U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 24: Maintenance

    If the door gasket requires replacement use IFIED SERVICE TECHNICIAN TO 7/8" diameter oval door gasket (Part # 650-920). INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF CONTROL Top View of pilot flame U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 25: Latch Adjustment

    10) Replace new gasket by gluing it in place. to center glass. 11) Install door onto stove and check the seal. 6) Remove glass from extrusions. When re- moving center glass, leave white insulation in place. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 26: Fan Maintenance

    The fan can only be ac- cessed from the back of the stove. 3) Unclip the black and white wires from the fan mo- tor. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 27 7) Remove burner. See diagram below. Note: Use a magnetic type screwdriver if possible. 8) Remove all 18 screws holding the burner tray assembly in place. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 28: Replacement Parts List

    918-025 Manual 730-525 Side Panel Door Assy (Left Side) *Not available as a replacement part. 560-031 Side Panel Door Hinge 904-258 Side Panel Door (c/w Hook) Magnet 948-255 Door Latch U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 29 Hex Key 3/16" AF 630-009 Gasket - Burner Tray / Air Passage 630-008 Gasket - Burner Tray / Firebox Air Shutter Gear Assembly (Male) *Not available as a replacement part. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 30 Side Glass 107) 936-243 Glass Gasket 108) 940-322/P Centre Glass 111) * Door Frame Fibre Paper 112) 750-015 Door Glass Extrusion 208) 940-325/P Wrap Glass *Not available as a replacement part. U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater...
  • Page 31: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 32 Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date Installed: _________________________________________________________ Serial No.: _____________________________________________________________ Regency and Ultimate are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Ultimate u37-ngUltimate u37

Table of Contents