WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour: CSA 2.17-2017
919-975
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
U39E-LP11 Propane
Installer: Please complete the details on the back cover
ANSI Z21.88-2017
and leave this manual with the homeowner.
CSA 2.33-2017
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
www.regency-fire.com
03.05.19

Advertisement

Table of Contents
loading

Summary of Contents for Regency Ultimate U39E Series

  • Page 1 Owners & Ultimate™ U39E Freestanding Gas Stove Installation Manual www.regency-fire.com MODELS: U39E-NG11 Natural Gas U39E-LP11 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of ®...
  • Page 3: Table Of Contents

    If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply. See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove...
  • Page 4: Unit Dimensions

    9 13 16 " (250mm) ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 5: Copy Of Safety Label For U39E Gas Stove

    NOTE: Regency units are constantly being ® This is a copy of the label that accompanies each ULTIMATE Direct Vent improved. Check the label on the unit and if there is Freestanding Gas Stove. We have printed a copy of the contents here for your a difference, the label on the unit is the correct one.
  • Page 6: Before You Start

    ANY SAFETY SCREEN, GUARD, OR CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS BARRIER REMOVED FOR SERVICING OR CLOTHING IGNITION. AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 7: Lighting Procedure

    If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply. See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove...
  • Page 8: Copy Of The Lighting Plate Instructions

    Colours: Black on Grey, except for parts indicated as being Red. Punch out .25" hole top right corner where indicated. Size: 100% w- 6.52" h- 11.13" Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® Apr 05/16: Created decal Apr. 26/16: Added Fr. Headers/warnings...
  • Page 9: Proflame Ii Remote Control Operating Instructions

    (*) The receiver may be independent or integral to the IFC hearth ap- pliance control module. The receiver instruction may not be indepen- dent when part of the IFC. Figure 2: Transmitter LCD Display Fig3: Battery Figure 3: Battery Compartment compartment. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 919-829 09.29.17...
  • Page 10 Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confi rms reception of the command. Figure 9 Figure 10 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 919-829 09.29.17...
  • Page 11 Keys (fi g.1) to turn on, off or adjust the fan speed (fi g. 14). A single “beep” will confi rm reception of the command. Figure 17 Figure 18 Figure 13 Figure 14 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 09.29.17 919-829...
  • Page 12 3rd battery is installed, then release the mode button only. 4. The screen will show either "Clr" or "Set" with the 1st mode being your option to disable or enable. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 919-829...
  • Page 13: Installer's Information

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 14: Specifications

    This Regency Mobile/Manufactured ® because the appliance's metal pedestal base Home Listed appliance comes factory Note: Failure to follow the instructions extends the full width and depth of the appliance.
  • Page 15: General Safety Information

    D Side Wall to Flue Centerline 20-1/2"/521 mm F Side Wall to Flue Centerline 11"/280 mm Minimum ceiling height is 36" / 914 mm from top of unit. Vent pipe clearances to combustibles1-1/4” (32mm) Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 16: Manufactured Mobile Home Additional Requirements

    Consult your servicing and proper operation. local building codes before beginning installation. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" section. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 17: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 18: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
  • Page 19 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove...
  • Page 20: Rigid Pipe Venting Systems

    Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 21: Installation Precautions

    Installer Wear gloves and safety glasses for protection. Exercise extreme caution when using ladders Horizontal Run (Feet) or on roof tops. Be aware of electrical wiring locations in walls and ceilings. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 22 4 feet total vertical and max. 4 feet total horizontal. Please note min. 1 foot between 90 elbows is required. Lengths do not include elbow indicated Vent restrictor position A (fully open). Refer to the “Venting Arrangement” section. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 23: Dv Stove Horizontal Vent Kit Installation

    When using snow blowers, make sure snow is not directed towards vent Note: if the centerline cannot be met, termination area. the adjustable sections will have to be cut. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 24 16. Attach the 90 elbow onto the pipe section by to make a tight seal between the cap and the sealing with Mill-Pac and securing with 3 of the standoff. #8 x 1/2" screws (black). Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 25: Dura-Vent Termination Kit

    Minimum components for a Dura-Vent Horizontal Installation: You will require the following components with Planning Your Dura-Vent Dura-Vent Horizontal Termination Kit your new Regency ® Direct Vent Freestanding Gas Installation Wall Thimble (required for combus- Stove. Please review your product to make sure you tible walls) have everything you need.
  • Page 26: Warranty

    7" diameter hole code requirements. is acceptable. Note: Riser Vent is only for use in above grade terminations. Diagram 3a Diagram 2 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 27 2. Frame the hole as shown in diagram 10. attach with screws provided. Apply decorative brass or chrome trim if desired. See diagram Diagram 5 Diagram 7 Diagram 10 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 28 4" the flashing to the roof with roofing rails, slide 2/12-7/12 5-1/2" storm collar over the pipe section and seal with a mastic. 7/12-12/12 6-3/4" 12/12-24/12 7-1/2" Diagram 13 24/12+ 12-1/2" Diagram 12 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 29: Converting A Class-A Metal Chimney To A Direct Vent System

    Insure that you are in fact, drilling into the metal on the chimney. Twist-lock the Termination Cap onto the Adaptor. (Diagram 3 and 4). Diagram 2 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 30: Gas Connection

    Diagram 5 Log Set: Ceramic fiber, 7 per set. 7. The connection between the appliance and the Retro Connector may be completed with sections of black direct vent pipe, together with an adjustable length. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 31: Conversion From Ng To Lp

    4. Open pedestal door and remove the chain from door which will allow door to 20. The burner aeration should be set to fall. 10. Unscrew the pilot orifice with the allen 1/2" open for LP. 5. R emove 2 screws that secure the front key and replace with the LPG pilot See aeration adjustment details in the door to the unit. One screw is on the left orifice in the kit. manual. hand side and the other on the right hand side. (Left side shown). 11. Reinstall new burner orifice LPG 21. Check for proper flame appearance and stamped #50 and tighten. glow on logs. Installer Notice: These instructions must be left with the appliance. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 01.30.19 920-050...
  • Page 32: Conversion To High Elevation

    Note: Screw should be snug, but do not over tighten 10) Check operation of flame control. Check for proper flame appearance and glow on logs. Note: Use a magnetic type screwdriver if possible. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 33: 885 S.i.t. Valve Description

    NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of ® installation or service. On Demand Pilot Light Important: This appliance has a timer built into the pilot light.
  • Page 34: Log Set Installation

    Place Rear Log A on the two pins on the rear log support. Place the Left Top Log D on the pin on Log B and on top of the cut-out on Log A. Pins on Rear Log Support Cutout Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 918-039b 04.05.18...
  • Page 35 10. Next, take the white Platinum Ember material (provided) and gently separate the layers until you have a fi ne layer to place onto the Embaglow (steel wool type media). Platinum Embers Notch 918-039b 04.05.18 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 36 12. Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other. If there is any fl ame hesitation, check that area for any blockage of the burner port. A)02-65 B)02-56 E)02-45 C)02-44 918-039b 04.05.18 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 37: Driftwood Log Set Installation

    Place Rear Log A on the two pins on the rear log support. Place the Left Top Log D on the pin on Log B and on top of the cut-out on Log A. Pins on Rear Log Support Cutout Regency U39E-11 ULTIMATE™ Freestanding Gas Stove 919-939 ® 10.15.18...
  • Page 38 10. Next, take the white Platinum Ember material (provided) and gently separate the layers until you have a fi ne layer to place onto the Embaglow (steel wool type media). Platinum Embers Notch Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ® 919-939 10.15.18...
  • Page 39 12. Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other. If there is any fl ame hesitation, check that area for any burner port blockage. 919-939 10.15.18 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 40: Wiring Diagram Without Thermostat

    The fan will not grounded three-prong recep- operate during a power outage. tacle. Do not cut or remove the grounding prong from this plug. EXTERNAL ANTENNA Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 41: Optional Wall Thermostat

    Connect the wires as per the wiring diagrams. to the 120V wires. Note: Preferable if the thermostat is installed on an interior wall. Regency ® offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.
  • Page 42: Operating Instructions

    This is the recommended procedure for operating the unit with a thermostatic set point. If a millivolt wall thermostat is required for bedroom installation or as preferred method of controlling the stove, see noted option. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 43: Battery Backup

    3. Install 4 AA batteries ensuring they are polarity correct. See diagram 4. 2. Press down on both tabs to remove battery compartment door. See diagrams 2 and 3. 4. Reverse steps 3-1. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 44: Automatic Convection Fan Operation

    Blower: Adjusting Flame Height Regency gas appliances use high tech blowers ® to push heated air farther into the room. It is not Your heater has an adjustable flame to tailor the look unusual for the fan to make a "whirring"...
  • Page 45: Maintenance

    AWAY TO AVOID BURNS OR CLOTH- some "cracking" and "ticking" sounds will be heard ote: If you have an incorrect flame pattern, ING IGNITION. YOUNG CHILDREN throughout the cycling process. contact your Regency dealer for further ® SHOULD BE CAREFULLY SUPER- instructions.
  • Page 46: Log Replacement

    5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement door from an authorized Regency dealer only, and follow ® Wraparound Assembly Door our step-by-step instructions for replacement.
  • Page 47: Fan Maintenance

    5. Lift fan off of the 2 pins, tip back and pull through firebox opening. Disconnect the green ground wire from the right side of the fan as soon as accessible. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 48: Valve Replacement

    13. Remove the valve tray and replace. 14. Reverse Steps 1-11 to complete. Stepper motor wire 6. If the fan is installed–disconnect the "COM" wire from the valve. 7. Disconnect the DC spark generator wires from the valve. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 49: Main Assembly

    904-258 Side Panel Door Magnet 948-255 Door Latch c/w Hook Flex Pipe 3" ID Hose Clamp 630-021 Fan Access Panel 730-019 Rear Panel 730-565 Firebox Baffle/Restrictor Assy (SEPARATE ILLUSTRATION ON GLASS DOOR FRONTS) Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 50: Burner & Log Assembly

    Wire Harness Battery Box Proflame II .584.922 911-127 Remote Control Battery Door IPI 911-037 Flame sensor 911-038 Flame Electrode 910-432 Pilot Tube with Nuts 911-187 Remote Battery Box 911-193 IFC Connector With Jumper *Not available as a replacement part. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 51: Door Assembly

    Brushed Nickel Wrap Door - Complete 101. 732-570 Door Gasket Kit 105. Ceramic Paper 107. 936-243 Glass Gasket 111. Door Frame Fibre Paper 208. 940-325/P Wrap Glass 209. 732-020 Door Mounting Bracket *Not available as a replacement part. Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 52: Warranty Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty Regency U39E-11 ULTIMATE™ Freestanding Gas Stove...
  • Page 53 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 54 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 55 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 56 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 57 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 58 Regency U39E-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 60 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ U38-39 Video Printed in Canada Regency is a trademark of FPI Fireplace Products International Ltd. ® © Copyright 2019, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

U39e-ng11U39e-lp11

Table of Contents