Regency Ultimate U39-NG1 Owners & Installation Manual

Direct vent freestanding gas stove

Advertisement

Direct Vent Freestanding Gas Stove
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-531c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
ULTIMATE U39
MODELS:
U39-NG1 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
www.regency-fi re.com
U39-LP1 Propane
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch:
do not use any phone in your
building.
 Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
 If you
cannot reach your gas
supplier, call the fi re department.
Owners &
04/05/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency Ultimate U39-NG1

  • Page 1 ULTIMATE U39 Owners & Installation Manual Direct Vent Freestanding Gas Stove www.regency-fi re.com MODELS: U39-NG1 Natural Gas U39-LP1 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: ...
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd. The Regency ® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the fl...
  • Page 3 DIMENSIONS ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 4: Table Of Contents

    Gas Connection ............25 High Elevation .............25 Conversion from NG to LP ..........26 Conversion to Lower BTU Rating ........29 Gas Pipe Pressure Testing ..........29 Aeration Adjustment ............30 Log Set Installation ............31 Wiring diagram ............34 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 5: Safety Label

    SAFETY LABEL ® label is located on the inside of the drop NOTE: Regency units are constantly This is a copy of the label that accompanies being improved. Check the label on the down pedestal door. each ULTIMATE Direct Vent Freestanding unit and if there is a difference, the label Gas Stove.
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 7: Before You Start

    SERIOUS HOUSE FIRE. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 8: Important Message

    fi rst. Consult the building authority having because the appliance's metal pedestal base jurisdiction to determine the need for a permit prior ® This Regency Mobile/Manufactured extends the full width and depth of the appliance. to starting the installation.
  • Page 9: General Safety Information

    8) Final check. Refer to the "Final Check" section. D Side Wall to Flue Centerline 20-1/2"/521 mm F Side Wall to Flue Centerline 11"/280 mm Minimum ceiling height is 36" / 914 mm from top of unit. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 10: Manufactured Mobile Home Additional Requirements

    When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 11: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 12: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 13 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 14: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 15: Installation Precautions

    Exercise extreme caution when using ladders or on roof tops. Be aware of electrical wiring locations in walls and ceilings. Vent Restrictor setting at Vent Restrictor setting at 30,000 Btu/h 38,000 Btu/h ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 16 4 feet total vertical and max. 4 feet total horizontal. Please note min. 1 foot between 90 elbows is required. Lengths do not include elbow indicated Vent restrictor position A (fully open). Refer to the "Venting Arrangement" section. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 17: Dv Stove Horizontal Vent Kit Installation

    Be sure to check vent vertical centerline of the starter collar termination area after snow falls, on the unit. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 18 Put a bead of Mill-Pac brick, concrete, or other types of around the appliance adapter and secure sidings. with 3 screws (#8 x 1/2, stainless steel). ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 19: Dura-Vent Termination Kit

    TERMINATION KIT COMPONENTS You will require the following components with Minimum components for a Dura-Vent Planning Your Dura-Vent Horizontal Installation: your new Regency ® Direct Vent Freestanding Installation Gas Stove. Please review your product to make Dura-Vent Horizontal Termination Kit sure you have everything you need.
  • Page 20 7" diameter hole is acceptable. Note: Riser Vent is only for use in above grade terminations. Diagram 3a Diagram 2 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 21 Step 2. Frame the hole as paint and attach with screws provided. Apply shown in diagram 10. decorative brass or chrome trim if desired. See diagram 7. Diagram 5 Diagram 7 Diagram 10 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 22: Cathedral Ceilings

    0/12 - 2/12 4" the problem. 2/12 - 7/12 5-1/2" Diagram 13 7/12 - 12/12 6-3/4" 12/12 - 24/12 7-1/2" 24/12+ 12-1/2" Diagram 12 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 23: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    fi ttings and ash dumps Adaptor using 3 sheet shall be secured in place and sealed before metal screws. installing a Direct Vent system within the Diagram 2. chimney. Diagram 2 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 24 fl ashing as needed to fi t chimney. Diagram opening and the mounting holes line up with sections of black direct vent pipe, together the masonry wall. with an adjustable length. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 25: Gas Connection

    Electrical: 120 V. 1.13A 60Hz. Circulation: Variable speed fan, 125/75 CFM. Log Set: Ceramic fi ber, 7 per set. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 26: Conversion From Ng To Lp

    1) Shut off the gas supply. 2) Open the front door and carefully remove the logs and lava rock. 9) Remove the black protection cap by hand from the high-low knob (Fig.1). Fig.4 Fig 1 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 27 Installation of the DC Sparker: provided in the kit. 1) Remove the back pedestal cover by unscrewing the 4 screws. 16) Pull off the pilot cap to expose the pilot orifi ce. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 28 10) Put on the plastic split bushing. 19) Check for gas leaks. 20) Check inlet and outlet pressures. 21) Check operation of fl ame control. 22) Check for proper fl ame appearance and glow on logs. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 29: Conversion To Lower Btu Rating

    2 screws. 13) Check operation of fl ame control. Check for proper fl ame appearance and glow on logs. Position the Log Bracket Restrictor between the Rear Log Bracket and the burner. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 30: Aeration Adjustment

    NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized Regency ® Installer at the time of installation or service. To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter.
  • Page 31: Log Set Installation

    Note: Install Optional Brick Panels prior to installing logs. 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. B)02-56 ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 32 B)02-56 and on top of the cutout on Log A)02-65. 10) Separate platinum embers and place around the lava rock on the burner. Avoid stacking platinum A)02-65 embers. D)02-46 B)02-56 C)02-44 Cutout ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 33 fl ows smoothly from one end of burner to the other. If there is any fl ame hesitation, check that area for any blockage of the burner port. A)02-65 A)02-65 B)02-56 E)02-45 E)02-45 C)02-44 Notch ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 34: Wiring Diagram

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 35: Optional Wall Thermostat

    Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring ® A wall thermostat may be installed if desired. Use the Regency Remote Control Kit approved correctly. This includes: Connect the wires as per the wiring diagrams.
  • Page 36: Operating Instructions

    The glass should be cleaned or the fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 37: Automatic Convection Fan Operation

    fl ame. useful heat output range the fan will shut off rates resulting in some "cracking" and automatically. "ticking" sounds will be heard throughout the cycling process. ® Regency Regency Gas Fireplace U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 38: Maintenance Instructions

    S E RV I C I N G A N A P P L I A N C E and should only be refi nished with heat resistant MUST BE REPLACED PRIOR TO paint (not with wall paint). Regency ® uses OPERATING THE APPLIANCE.
  • Page 39: Log Replacement

    1) Install both center produce. In the event that you break your glass and side glass by impact, purchase your replacement door from onto extrusions an authorized Regency ® dealer only, and follow as per diagram. our step-by-step instructions for replacement.
  • Page 40: Fan Maintenance

    2) Remove the Heat Shield from the DC Spark Box. 3) Place 1 AA battery into the DC Spark Box by opening the battery compartment. 4) Reverse steps to put back in place. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 41: Removing Valve

    You can access it through the front now that the control panel is off, or you can access it through the rear pedestal cover plate. 8) Carefully remove the logs and lava rock. 9) Remove burner. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 42: Parts List

    *Not available as a replacement part. 904-258 Side Panel Door Magnet 948-255 Door Latch c/w Hook Flex Pipe 3" ID Hose Clamp 910-233 Thermodisc - Fan Auto/On/Off Mounting Bracket - Thermodisc ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 43: Burner & Log Assembly

    Burner Assembly (NG/LP) 260-565 Air Shutter Gear Assembly - Female 904-565 Hex Key 3/16" AF 630-009 Gasket-Burner Tray/Air Passage Air Shutter Gear Assembly - Male *Not available as a replacement part. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 44: Door Assemblies

    Brushed Nickel Wrap Door - Complete 101) 650-920 Door Gasket Kit 105) Ceramic Paper 107) 936-243 Glass Gasket 111) Door Frame Fibre Paper 208) 940-325/P Wrap Glass *Not available as a replacement part. ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 45 NOTES ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 46 NOTES ® Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove...
  • Page 47: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evalu- ated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 48 Limited Lifetime Warranty to the original purchaser of ® a Regency Product. See the inside back cover for details. ® Register your Regency online at http://www.regency-fi re.com Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________...

This manual is also suitable for:

Ultimate u39-lp1Ultimate u39

Table of Contents