Kyocera KM-2540 Service Manual page 52

Fax system (p)v
Hide thumbs Also See for KM-2540:
Table of Contents

Advertisement

3LH
Maintenance
item No.
Setting the system (communication 3)
U670
Description
Makes settings for fax transmission regarding the communication.
Purpose
To reduce transmission errors when a low quality line is used.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set.
The screen for the selected item appears.
Display
V.34 MODEM
V.34 SYM 3429Hz
V.34 SYM 3200Hz
V.34 SYM 3000Hz
V.34 SYM 2800Hz
Enabling/disabling V.34 communication
Sets whether V.34 communication is enabled/disabled for transmission and reception.
1. Change the setting using the numeric keys.
Display
1: ON
2: TX
3: RX
4: OFF
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the V.34 symbol speed (3429 Hz)
Sets if the V.34 symbol speed 3429 Hz is used.
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: ON
2: OFF
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the V.34 symbol speed (3200 Hz)
Sets if the V.34 symbol speed 3200 Hz is used.
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: ON
2: OFF
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the V.34 symbol speed (3000 Hz)
Sets if the V.34 symbol speed 3000 Hz is used.
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: ON
2: OFF
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
1-3-30
Description
Description
Enables or disables V.34 communication.
Sets the V.34 symbol speed (3429 Hz).
Sets the V.34 symbol speed (3200 Hz).
Sets the V.34 symbol speed (3000 Hz).
Sets the V.34 symbol speed (2800 Hz).
Description
V.34 communication is enabled for both transmission and reception.
V.34 communication is enabled for transmission only.
V.34 communication is enabled for reception only.
V.34 communication is disabled for both transmission and reception.
Description
V.34 symbol speed 3429 Hz is used.
V.34 symbol speed 3429 Hz is not used.
Description
V.34 symbol speed 3200 Hz is used.
V.34 symbol speed 3200 Hz is not used.
Description
V.34 symbol speed 3000 Hz is used.
V.34 symbol speed 3000 Hz is not used.