Maintenance
item No.
Setting the system (communication 1)
U607
Description
Makes settings for fax transmission regarding the communication.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set.
The screen for the selected item appears.
Display
REDIAL INTERVAL
TX SPEED
RX SPEED
REMOTE MODE
CALL INTERVAL
DC LOOP DETECT
DIS 4BYTE FIXED
Setting the auto redialing interval
Change the setting to prevent the following problems: fax transmission is not possible due to too short redial
interval, or fax transmission takes too much time to complete due to too long redial interval.
1. Change the setting using the numeric keys.
Description
Redialing interval
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the communication starting speed
Sets the initial communication speed when starting transmission. When the destination unit has V.34 capabil-
ity, V.34 is selected for transmission, regardless of this setting.
1. Change the setting using the numeric keys.
Display
1: 144
2: 96
3: 48
4: 24
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the reception speed
Sets the reception speed that the sender is informed of using the DIS or NSF signal. When the destination unit
has V.34 capability, V.34 is selected, regardless of the setting.
1. Change the setting using the numeric keys.
Display
1: 144
2: 96
3: 48
4: 24
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Description
Description
Sets the auto redialing interval.
Sets the communication starting speed.
Sets the reception speed.
Sets the mode for remote switching.
Sets the transmission intervals.
Sets the loop current detection before dialing.
Sets the DIS signal to 4 bytes.
Description
V.17, 14400 bps
V.17, 9600 bps
V.27ter, 4800 bps
V.27ter, 2400 bps
Description
V.17, V.33, V.29, V.27ter
V.29, V.27ter
V.27ter
V.27ter (fallback only)
Setting range
1 to 9 (min.)
3LH
1-3-11