Maintenance
item No.
Setting the continuous detection time for remote switching
U605
Sets the detection time when continuous detection is selected for remote switching. (This setting item will be
displayed, but the setting made is ineffective.)
1. Change the setting using the numeric keys.
Description
Continuous detection time for remote switching
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the initial condition of fax image scanning quality
Set to the resolution that is most frequently used by the user.
1. Change the setting using the numeric keys.
Display
1: S
2: F
3: SF
4: UF
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No.
is displayed.
Setting the system (operation unit and display)
U606
Description
Makes settings for fax transmission regarding the operation unit and display.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set.
The screen for the selected item appears.
Display
ALARM TURN OFF
DATE PATTERN
RESO. LOCK(FAX)
DENS. LOCK(FAX)
REPORT SKIP
Setting the conditions under which an error indicator turns off
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: RESET
2: COMM
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Description
Description
Standard
Fine
Super fine
Ultra fine
Description
Sets the conditions under which an error indicator turns off.
Sets the date format.
Sets if the image scanning quality in fax mode is initialized.
Sets if the scanning density in fax mode is initialized.
Sets whether to skip unregistered one-touch key numbers on the list.
Description
An error indicator turns off only when the reset key is pressed.
An error indicator turns off when any key is pressed, an original is
inserted or the next transmission is started.
Setting range
0 to 255 (x 5 : ms)
3LH
1-3-9