Siemens SCALANCE X-200 Configuration Manual page 145

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

Frames In
Displays the number of received frames.
Frames Out
Displays the number of sent frames.
Utilization
Displays the port utilization as a percentage (%). If the bus utilization is less than 1%,
nothing is displayed. Depending on the frame length (system dependent), the display can
deviate by up to 20% since the proportion of pauses between frames increases the shorter
the frame.
Max. Utilization
Displays the peak value of port utilization as a percentage (%).
Note
The Utilization value is calculated from the incoming frames. Here, both correct and bad
frames are relevant. Outgoing frames are not taken into account in the calculation of this
value.
Syntax of the Command Line Interface
Table 5- 39
Command
info
types
sizes
errors
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
Statistic - CLI\STAT>
Description
Shows statistical information on sent and received frames.
Displays information on the type of the sent and received frames.
Displays information on the length of the sent and received frames.
Displays information on bad sent and received frames.
Menus in the WBM
5.5 the Statistics menu
Comment
145