Menus in the WBM
5.4 The Switch menu
Syntax of the Command Line Interface
Table 5- 37
Command
info
dcpport [ports]
<enabled | disabled>
5.4.10

Loop Detection Config

Loop Detection Configuration
On this page, you specify for the ports for which loop detection will be activated. These ports
send test frames. If these frames are sent back to the device, there is a Loop.
Note
Note that the functions of the "Loop Detection Configuration" WBM menu are not available
for X-200IRT.
If the frames are received again at another port of the same device, there is a "Local Loop"
involving this device.
If the sent frames are received again at the same port, there is a "Remote Loop" involving
other network components.
Note
Note that loop detection is only possible at ports that were not configured as ring ports.
140
Switch DCP - CLI\SWITCH\DCP>
Description
Displays the current DCP settings.
Enables or disables the sending of DCP frames on one
or more ports.
Example:
The command "dcpport 1,2,3 rx" specifies that DCP
frames are only received on ports 1-3.
Configuration Manual, 03/2015, C79000-G8976-C285-06