Test Report; Bell Test - Bosch Ultima 862 Quick Reference Manual

Solution control panel
Table of Contents

Advertisement

Solution Ultima 862
STAY Mode 2 Zones - Program
1.
Enter the Installer Code or Master Code
followed by 4 and the # key.
[eg. 1234 + 4 + #].
2.
Enter the Zone Number that you want the
system to automatically isolate followed by the
* key.
Repeat if more than one zone to be
automatically isolated when armed in STAY
Mode 2.
3.
Press the # key to exit.
Fault Analysis
1.
Press and hold the 5 key until two beeps are
heard.
2.
Zone Indicators will display FAULT condition
(see table below).
3.
Press # key to exit.
Zone
FAULT Condition
LED
1
System Fault
2
RF Low Battery
3
Zone Tamper
4
Sensor Watch
5
RF Sensor Watch
6
Communication Fail
Modem Call (Alarm Link)
1.
Press and hold the 6 key until two beeps are
heard.
Latching Outputs (Reset)
1.
Press and hold the 7 key until two beeps are
heard.
Quick Reference Guide
Press and Hold Button 1
To Determine Fault
1 = Battery Fail
2 = Date/Time
3 = RF Rx Jamming
RF Rx Tamper
RF Rx Comm's Fail
4 = Horn Speaker Fail
5 = Telephone Line Fail
6 = E2 Fail
7 = Fuse Fail
8 = AC Fail
Press and Hold Button 2
To Determine Fault
Displays Zones (1 – 8) that
registers RF Low Battery
Press and Hold Button 3
To Determine Fault
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 4
To Determine Fault
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 5
To Determine Fault
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 6
To Determine Fault
1 = Receiver 1 Fail (Dialler)
2 = Receiver 2 Fail (Dialler)
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
Codepad Buzzer Tone
1.
Press and hold the 8 key until the desired
buzzer tone has been reached.
2.
Press the # key to exit.

Test Report

1.
Press and hold the 9 key until two beeps are
heard.
Speaker Test
1.
Press and hold the 1 key until two beeps are
heard.
The speaker will sound for two
seconds.

Bell Test

1.
Press and hold the 2 key until two beeps are
heard. The piezo will sound for two seconds.
Strobe Test (Toggle On/Off)
1.
Press and hold the 3 key until three beeps are
heard to turn the strobe on.
2.
Press and hold the 3 key until two beeps are
heard to turn the strobe off.
Telco Arm Sequence
1.
Enter your Installer Code or Master Code
followed by 3 and the # key.
[eg. 1234 + 3 + #].
2.
Press 1 followed by the # key.
3.
Enter the Call Forward On sequence.
4.
Press the # key to exit.
Telco Disarm Sequence
1.
Enter your Installer Code or Master Code
followed by 3 and the # key.
[eg. 1234 + 3 + #].
2.
Press 2 followed by the # key.
3.
Enter the Call Forward Off sequence.
4.
Press the # key to exit.
7
(Call Forward On)
(Call Forward On)

Advertisement

Table of Contents
loading