Location - Bosch Ultima 862 Quick Reference Manual

Solution control panel
Table of Contents

Advertisement

Solution Ultima 862

Location 348

Codepad Duress Report
Location 349 - 350
Codepad Panic Report
Location 351 - 352
Codepad Fire Report
Location 353 - 354
Codepad Medical Report
Location 355
Codepad Reporting Options
Location 356 - 357
System Status - Fuse Fail Report
Location 358 - 359
System Status - Fuse Fail Restore Report
Location 360 - 361
System Status - AC Fail Report
Location 362 - 363
System Status - AC Fail Restore Report
Location 364 - 365
System Status - Low Battery Report
Location 366 - 367
System Status - Low Battery
Restore Report
Location 368 - 370
System Status - Access Denied
Location 371
System Status Reporting Options
Location 372 - 378
Test Report Time
(Automatic)
Location 379
Test Reporting Dialler Options
Quick Reference Guide
Location 349 = Tens Digit
Location 350 = Units Digit
Location 351 = Tens Digit
Location 352 = Units Digit
Location 353 = Tens Digit
Location 354 = Units Digit
0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
8 = Report To Receiver 2 Only If Receiver 1 Fails
Location 356 = Tens Digit
Location 357 = Units Digit
Location 358 = Tens Digit
Location 359 = Units Digit
Location 360 = Tens Digit
Location 361 = Units Digit
Location 362 = Tens Digit
Location 363 = Units Digit
Location 364 = Tens Digit
Location 365 = Units Digit
Location 366 = Tens Digit
Location 367 = Units Digit
Location 368 = Code Retry Limit (0 = Unlimited)
(Code Retry)
Location 369 = Tens Digit
Location 370 = Units Digit
0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
8 = Report To Receiver 2 Only If Receiver 1 Fails
Location 372 = Hour Of Day (Tens Digit)
Location 373 = Hour Of Day (Units Digit)
Location 374 = Minute Of Day (Tens Digit)
Location 375 = Minute Of Day (Units Digit)
Location 376 = Test Report (Tens Digit)
Location 377 = Test Report (Units Digit)
Location 378 = Repeat Interval In Days
0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
8 = Report To Receiver 2 Only If Receiver 1 Fails
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
7 15
7 14
7 13
10 3
10 8
10 2
10 7
10 1
10 6
368
369 370
6
7 12
372 373 374 375
376 377
0 0 0 0
7 1
H
H
M
M
Tens/Units
Report Code
13
6
1
1
378
0
Interval
1

Advertisement

Table of Contents
loading

Table of Contents