Bosch Ultima 862 Quick Reference Manual page 11

Solution control panel
Table of Contents

Advertisement

Solution Ultima 862
Zone Types
Zone Type
0
Instant
1
Handover
2
Delay-1
3
Delay-2
4
Reserved
5
Reserved
6
24 Hr Medical
7
24 Hr Panic
Zone Pulse Count
The pulse count allows you to program how many pulses (0 – 15) need to be registered within the pulse count
time to activate an alarm.
Zone Pulse Count Time
Option
20ms Loop Response Time
0
0.5 Seconds
1
1 Second
2
2 Seconds
3
3 Seconds
4
4 Seconds
5
5 Seconds
6
10 Seconds
7
15 Seconds
Zone Options 1
Option
Description
1
Lockout Siren/Dialler
2
Delay Alarm Report
4
Silent Alarm
8
Sensor Watch
Keyswitch Zone Options
The keyswitch zone options replace Zone Options 1 only for the zones that have been programmed to operate
as a keyswitch zone.
Quick Reference Guide
Description
Zone Dialler Options
Option
0
No Zone Reports Allowed
1
Report To Receiver 1
2
Report To Receiver 2
4
Report To Both Receiver 1 & Receiver 2
8
Report To Receiver 2 Only If Receiver 1 Fails
Option
0
Latching Arm and Disarm In AWAY Mode
1
Latching Arm In AWAY Mode
2
Latching Disarm From AWAY Mode Or STAY Mode
4
Latching Arm and Disarm In STAY Mode
5
Latching Arm In STAY Mode
6
Latching Disarm From STAY Mode
8
Momentary Arm and Disarm In AWAY Mode
9
Momentary Arm In AWAY Mode
10
Momentary Disarm From AWAY Mode Or STAY Mode
12
Momentary Arm and Disarm In STAY Mode
13
Momentary Arm In STAY Mode
14
Momentary Disarm From STAY Mode
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
Zone Type
Description
8
24 Hr Hold-Up
9
24 Hr Tamper
10
Reserved
11
Keyswitch
12
24 Hr Burglary
13
24 Hr Fire
14
Chime
15
Not Used
Option
150 ms Loop Response Time
8
20 Seconds
9
30 Seconds
10
40 Seconds
11
50 Seconds
12
60 Seconds
13
90 Seconds
14
120 Seconds
15
200 Seconds
Zone Options 2
Option
1
Isolated In STAY Mode 1
2
Zone Isolation Allowed
4
Forced Arming Allowed
8
Zone Restore Report Allowed
Group
Description
11
Group

Advertisement

Table of Contents
loading

Table of Contents