Honeywell OMNI 408 Installation And Setup Manual page 45

Fbii hardwired/wireless system
Table of Contents

Advertisement

followed by the 2-digit RF question number to access the RF questions. If the bit IS enabled, the
procedure now is to press the [BYPASS] key followed by the 2-digit RF question number.
RF TROUBLE SOUNDER - Choosing this option causes the keypad sounder to pulse until either a
valid user is entered or the trouble is restored, in the case of a RF low battery, RF supervision, or RF
tamper condition.
AC LOSS SOUNDER - Choosing this option causes the keypad sounder to pulse after a 15-minute AC
power loss.
EUROPEAN RING DETECT - Select this option only if the system uses a European telephone
system. This option changes the ring detection frequency used for Automatic Answer mode for remote
(downloading) purposes only, according to the programmed ring count (see Programming Question 09,
Location 2). If you choose this option, the ring detection frequency range is 10 - 90Hz. If not, the
frequency range is 16 - 90Hz.
European Ring Detect has not been evaluated by UL and must not be used for UL
U L
installations.
QUESTION 10
SYSTEM OPTIONS, KEYPAD DISPLAY, ARMING FEATURES,
PAGER EVENTS
There are 4 locations (L1-L4).
Question 10, L1
Bell Ring on Cancel, Arm Bell Test, Disarm Bell Test, & Bell Test Chirp
Digit
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
BELL RING ON CANCEL - Choosing this option causes the bell to ring for 1 second after kissoff of
cancel to central station.
ARMING BELL TEST - Choosing this option causes two 1-second bell outputs when system arms (or
a double chirp if the Bell Test Chirp option is selected).
BELL RING ON
ARM BELL
CANCEL
TEST
Section 7 - System Programming
DISARM BELL
TEST
NONE
DEFAULT = 0000
Default = 0
BELL TEST
CHIRP
7–13