Honeywell OMNI 408 Installation And Setup Manual page 52

Fbii hardwired/wireless system
Table of Contents

Advertisement

OMNI-408/OMNI-408EU Installation and Setup Guide
Zone Alarm Codes
As specified previously, locations L3 and L4 of the zone questions represent the Alarm code that is
reported to the central station.
NOTE: Zones transmit to the central station unless these digits are defined as AA for any
individual zone; or unless the local dialer option is selected for all zones in Question 06,
Location 3.
Based on the dialer format selected, enter the Alarm code as follows:
STANDARD FORMAT (3X1 or 4X1): Enter the desired single-digit Alarm code in location L3 for
the specific zone. The value placed in L4 is not used.
EXTENDED (3X1 Ext. or 4X1 Ext.): Enter the desired first digit of the Alarm code for the specific
zone in location L3. Enter the second digit in L4.
PARTIAL EXTENDED (3X1 Part. Ext. or 4X1 Part. Ext.): Enter the desired digit in both
locations L3 and L4 for the specific zone. This generates a single-digit transmission for alarms and
troubles (the second digit is not used) and an extended transmission for all system conditions such
as restores, bypasses, openings/closings, etc. (the second digit is used).
3X2 or 4x2: Enter the desired first digit of the Alarm code in location L3 and the second digit in L4
for the specific zone. Both digits are used for all transmissions.
ADEMCO 4X2 EXPRESS: Enter the desired first digit of the Alarm code into the first location and
the second digit into the second location.
ADEMCO POINT ID (PID) Format: The digit entered in the first location selects the PID Event
code to be transmitted; refer to Appendix A for the PID Event Codes to be selected.
The selections on the charts below are used to disable supervision for each zone.
For more information on CS Reporting Formats, refer to Appendix A at the back of this guide.
QUESTIONS 11 - 18 ZONES 1 - 8
There are 4 locations (L1-L4) within each of these questions that define the operation of the zones.
Enter a 2-digit number in locations L1 and L2 from the zone chart for the desired zone type. Enter the
desired Alarm code in locations L3 and L4 for this zone based on the dialer format selected.
QUESTION 11
ZONE 1 TYPE & CS CODE
Question 11, L1 & L2 - Zone 1 Type
Question 11, L3 & L4 - CS Code for Zone 1
Zone 1 = Delay (Entry/Exit) w/CS Reporting code = 31
7–20
DEFAULT = 2031
Default = 20
Default = 31