Pager Follow-Me Displays; Entering Pager Follow-Me Phone Numbers - Honeywell OMNI 408 Installation And Setup Manual

Fbii hardwired/wireless system
Table of Contents

Advertisement

OMNI-408/OMNI-408EU Installation and Setup Guide
For example, the 24-Hr Keypad Panic can be initiated by pressing both keypad Panic keys at the same
time. The panic condition can be silent (no bell output) or audible, based on the programming option.
NOTE: The default value for Panic is audible.
Audible Panic, Fire, and Audible Auxiliary can be RESET BY ENTERING ANY VALID USER CODE
or using the asterisk [*] key.

Pager Follow-Me Displays

The display shown on your pager will be "ACCTEXXX":
Where:
"ACCT" is the 4-digit central station #2 account number.
"E" is the event code. There are 4 event types: alarms, troubles, openings, and closings. These event
codes are as follows:
Openings = 0, Closings = 1, Alarm or Trouble = 9
If multiple events occur, the event with the highest priority is displayed. Events ranked from
highest to lowest priority are alarms, trouble, open, and close.
"XXX" is, depending on the event, either the zone (01-08) or user designation (1-14).
USER DESIGNATION
1-6
7
8
9-14
U L
The Pager Feature has not been evaluated by UL and must not be used for UL installations.

Entering Pager Follow-Me Phone Numbers

To enter pager follow-me phone number: press [#] [5] [8], new pager no., [#]
Where:
[#] [5] [8] — Accesses end user pager number programming (acknowledge tone should be emitted).
New pager no. — Including the [CODE] key, allows 16 digits for the pager phone number.
[#] — When pressed after entering changes, will save new pager number, null out remaining locations,
and exit pager-programming mode. An acknowledge tone should be emitted.
[*] — Exits #58 mode without saving changes. An acknowledge tone should be emitted.
NOTES:
• If no key is pressed for 10 seconds, the mode times out and exits automatically without saving
changes.
• [CODE] — Optional command that, if pressed, will insert a "C" or 2-second pause.