No
Parameter
13
GRQ SEND
14
USE MULTI E.164
15
E.164 LISTS
16
GK REGISTERED
D EFAULT DATA
9 7 7 B
SEE DESCRIPTION
A CTION
9 7 8 B
1) Press Transfer button and enter 836.
Display shows the first available option.
2) Enter H.323 GK option via dial keypad.
OR
Press Volume button to make selection and
press Right Soft button to move cursor.
3) Enter H.323 GK option data.
OR
Press Volume button to make selection and
press Right Soft button to save and return step 3.
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
R ELATED ITEMS
9 7 9 B
MMC 834
Samsung Business Communications
Select ON or OFF for use of Gatekeeper RAS Re-
quest(GRQ) messages.
When this option is set to ENABLE, the E.164 identi-
fier can be assigned.
This is the E.164 identifier used by the H.323 trunk
when registering with the gatekeeper. There is a
maximum 32 E.164 identifier lists with a digit string
length of 16 digits.
Display the status of registration to the Gatekeeper.
H.323 OPTIONS
CHAPTER 2. MMC Programming
Description
G
K CONNECTION
U
U
DISABLE
GK ROUTING
D
I SABLE
U
U
G
K ROUTING
U
U
ENABLE
Default
OFF
DISABLE
NONE
NO
DISPLAY
2-359