Samsung OfficeServ 7000 Series Programming Manual page 204

Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

CHAPTER 2. MMC Programming
Timer Name
MS LED ON TIME
OFF HOOK RING INT
OHVA ANSWER TIME
PAGE TIME OUT
PAGE TONE TIME
PARK RECALL TIME
AP-MMC LOCK TIME
PERI UCD REPORT
POWER DOWN TIME
RECALL
DISCONNECT
RECALL WAIT TIME
ROUTE OPTIMISE
SMDR START /DP
SMDR START /DTMF
SYS HOLD RECALL
2-162
Default
Range Unit
5
1-10 SEC
15
1-250 SEC
10
1-250 SEC
20
1-250 SEC
500
100-2500
MSEC
45
0-250 SEC
5
1-60 MIN
5
3-99 SEC
2000
500-9900
MSEC
2
1-250 MIN
15
0-250 SEC
5
0-250 SEC
30
1-250 SEC
15
1-250 SEC
45
0-250 SEC
Description
This timer controls the duration a Manual
Signalling key will remain on after use.
This timer controls the time between ring
bursts to a user who has a camped-on call.
This timer controls the time allowed to answer
an OHVA call before automatic rejection.
This timer controls the duration of a page
announcement.
This timer controls the duration of tone burst
heard over the page prior to the page
announcement.
This timer controls how long a call is parked
before recalling to the call park originator.
This timer monitors the PCMMC / WebMMC /
Installer activity, drops the link if no action is
created by PCMMC and returns the system
back to secure program status.
This timer determines the interval between
periodic UCD reports provided to an SIO port.
This timer monitors the power to the ROM
pack to begin shutdown status.
This is the time an attendant recall will ring
before being disconnected.
This is the time any recall(hold or transfer)
continues to recall at your station before it
recalls to the operator.
When a call is made via Q-SIG signalling,
route optimization is activated after this time.
This grace period timer starts SMDR
recording for rotary dialing.
This grace period timer starts SMDR recording
for touchtone dialling. This timer also controls
the LCD duration timer on the phones. The
duration time displayed and the SMDR time
duration will be the same.
This timer determines the time calls can be
left on hold before recalling to the holding
station. This is a system-wide timer. Setting
the timer to 000 means that no recalling will
take place.