General Description; General Description; U1000 Model Selection; Control Mode Selection - YASKAWA U1000 Technical Manual

Matrix drive low harmonic regenerative drive for industrial applications 200 v class: 7.5 to 75 kw (10 to 100 hp nd) 400 v class: 5.5 to 580 kw (7.5 to 775 hp nd)
Hide thumbs Also See for U1000:
Table of Contents

Advertisement

1.2

General Description

u

U1000 Model Selection

Refer to
Table 1.1
for drive selection depending on Normal Duty (ND) or Heavy Duty (HD) rating.
Note:
The models and capacities in shown here are based on standard settings and operation conditions. Higher carrier frequencies and higher
ambient temperatures require derating.
Three-Phase 200 V Class
Heavy Duty Rating Normal Duty Rating
Drive Model
Rated Output
Current (A)
2o0028
2o0042
2o0054
2o0068
2o0081
2o0104
2o0130
2o0154
2o0192
2o0248
u

Control Mode Selection

Table 1.2
gives an overview of the U1000 control modes and their various features.
Motor Type
Control Mode
Parameter Setting
Basic Description
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
Table 1.1 U1000 Models
Rated Output
Current (A)
22
28
28
42
42
54
54
68
68
81
81
104
104
130
130
154
154
192
192
248
Table 1.2 Control Modes and Features
Induction Motors
V/f
V/f w/PG
OLV
A1-02 = 0
A1-02 = 1
A1-02 = 2
V/f control
Open Loop
V/f control
using motor
Vector control
speed feedback
Three-Phase 400 V Class
Heavy Duty Rating Normal Duty Rating
Drive Model
Rated Output
Current (A)
4o0011
4o0014
4o0021
4o0027
4o0034
4o0040
4o0052
4o0065
4o0077
4o0096
4o0124
4o0156
4o0180
4o0216
4o0240
4o0302
4o0361
4o0414
4o0477
4o0590
4o0720
4o0900
4o0930
Permanent Magnet Motors
CLV
OLV/PM
AOLV/PM
A1-02 = 3
A1-02 = 5
A1-02 = 6
Open Loop
Open Loop
Closed Loop
Vector control
Vector control
Vector control
for PM motors
for IPM motors

1.2 General Description

Rated Output
Current (A)
9.6
11
11
14
14
21
21
27
27
34
34
40
40
52
52
65
65
77
77
96
96
124
124
156
156
180
180
216
216
240
240
302
302
361
361
414
414
477
477
590
590
720
720
900
900
930
Comments
CLV/PM
Default Setting is
A1-02 = 7
OLV control
(A1-02 =2)
Closed Loop
Vector control
for PM motors
1
31

Hide quick links:

Advertisement

Table of Contents
loading