5
Installing the boiler
5.2

Test ports

Flue gas readings and combustion air temperature
readings are taken exclusively at the dedicated testing
ports.
Follow the directions in the instructions for the Logatop
BE oil burner.
18
Fig. 13 Installing the flue/air connector (included with
the venting system)
1
Air intake test port
2
Flue gas test port
Logano GB125 BE US/CA - Subject to technical modifications.