To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
3. Push connectors through back panel.
4. Remove screws and rear wiring channel from
range.
5. Remove screws and back panel from range.
6. Slide grommet with power cord from panel
7. Reverse procedure for installation.

Cooling Blower Motor Removal

1. Remove back panel (see Back Panel Removal).
2. Remove three screws from blower motor.
3. Remove four screws and blower mount from
range.
4. Mark and disconnect three connectors and
remove blower motor.
5. Reverse procedure for installation.
©2012 Viking Preferred Service
!
WARNING

Terminal Block Removal

1. Access the rear of the range.
2. Remove screws and access door from back
cover.
.
3. Mark and disconnect all connectors from
terminal block.
4. Remove screws and terminal block from range.
5. Reverse procedure for installation.