Temperature Sensor (Rtd) Removal; Cooling Blower Motor Removal - Viking RVGR3305B Service Manual

30 inch gas range
Hide thumbs Also See for RVGR3305B:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Temperature Sensor (RTD) Removal

Note: The following procedure explains how to
replace the RTD properly. An option to this
procedure would be to pull the RTD through
the oven cavity, cut the two wires, and splice
in the replacement RTD with the use of two (2)
ceramic wire nut connectors.
1. Remove oven door (see Door Assembly Removal).
2. Access control board (see DSI Module Accessed).
3. Disconnect RTD Molex connector from control board.
4. Remove any wire ties as required.
5. Route RTD wires through burner box area and out
back of range.
6. Remove screws and RTD sensor from the oven liner.
7. Reverse procedure for installation.
©2013 Viking Preferred Service

Cooling Blower Motor Removal

1. Remove back panel (see Back Panel Removal).
2. Remove main top (see Main Top Removal).
3. Remove three screws from blower motor.
4. Remove four screws and slide cooling fan cover
forward to access blower motor.
5. Mark and disconnect three connectors and remove
blower motor.
6. Reverse procedure for installation.
Disassembly
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crvgr3305bBzrvgr3305b

Table of Contents