Cooling Blower Motor Removal; Terminal Block Removal; Orifi Ce Removal - Viking DSCD130 Service Manual

Hide thumbs Also See for DSCD130:
Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Cooling Blower Motor Removal

Condition Requirements:
Back Panel Removed
1. Remove three screws from blower motor.
2. Remove four screws and blower mount from range.
3. Mark and disconnect three connectors and remove
blower motor.
4. Reverse procedure for installation.
34

Terminal Block Removal

Condition Requirements:
Rear of Range Accessed
1. Remove screws and access door from back cover.
2. Mark and disconnect all connectors from terminal
block.
3. Remove screws and terminal block from range.
3. Reverse procedure for installation.
Orifice Removal
Condition Requirements:
Burner Base Removed
Note: Use a socket with a small amount of putty to
keep the orifice during removal.
1. Remove orifice from jet holder.
Note: Use a socket with a small amount of putty to
keep the orifice during installation. Ensure that
the putty does not block the hole of the orifice.
2. Reverse procedure for installation.
©2010 Viking Preferred Service