Cooling Blower Motor Removal; Terminal Block Removal; Orifice Removal - Viking RDSCD230-5B Service Manual

30 inch dual fuel range
Hide thumbs Also See for RDSCD230-5B:
Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
3. Push connectors through back panel.
4. Remove screws and rear wiring channel from range.
5. Remove screws and back panel from range.
6. Slide grommet with power cord from panel.
7. Reverse procedure for installation.

Cooling Blower Motor Removal

1. Remove back panel (see Back Panel Removal).
2. Remove three screws from blower motor.
3. Remove four screws and blower mount from range.
4. Mark and disconnect three connectors and remove
blower motor.
5. Reverse procedure for installation.
36

Terminal Block Removal

1. Access the rear of the range.
2. Remove screws and access door from back cover.
3. Mark and disconnect all connectors from terminal
block.
4. Remove screws and terminal block from range.
5. Reverse procedure for installation.

Orifice Removal

1. Remove grates, burner caps, and burner heads from
burner base assembly.
2. Remove orifice from jet holder.
3. Reverse procedure for installation.
©2012 Viking Preferred Service

Hide quick links:

Advertisement

Table of Contents
loading