Troubleshooting
Selector and Thermostat Characteristics
The tables show the operating characteristics of the selector and thermostat positions. The
selector and thermostat are potentiometers (variable resistors) whose resistance varies per user
selections. The selected resistance informs the board of the user's selections. All values are
approximate.
Selector Position
Off
Bake
Convection Bake
Tru Convection
Convection Roast
Convection Broil
Hi Broil
Med Broil
Low Broil
Self Clean
Resistance checks are made on the selector wire harness with the selector wire harness
disconnected from the board at location P14 and thermostat disconnected. The harness is
connected to P14 for voltage checks.
Thermostat
Position
Off
200°F
300°F
400°F
500°F
Broil
Clean
Resistance checks are made on the thermostat wire harness with the thermostat wire harness
disconnected from the board at location P14 and selector disconnected. The harness is
connected to P14 for voltage checks.
32
Resistance - Voltage
blue to yellow
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
Resistance - Voltage
blue to yellow
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
10.0 kW
5 VDC
Resistance - Voltage
blue to black
∞
5 VDC
374 W
0.24 VDC
1.60 kW
0.86 VDC
2.60 kW
1.47 VDC
3.85 kW
2.08 VDC
5.00 kW
2.64 VDC
6.14 kW
3.21 VDC
7.20 kW
3.66 VDC
8.28 kW
4.21 VDC
9.41 kW
4.82 VDC
Resistance - Voltage
blue to orange
∞
5 VDC
8.75 kW
4.32 VDC
6.88 kW
3.37 VDC
4.75 kW
2.50 VDC
2.89 kW
1.56 VDC
2.19 kW
1.11 VDC
696 W
0.36 VDC
Resistance - Voltage
black to yellow
∞
0
9.48 kW
4.74 VDC
8.42 kW
4.12 VDC
7.28 kW
3.49 VDC
6.01 kW
2.88 VDC
4.81 kW
2.31 VDC
3.78 kW
1.80 VDC
2.72 kW
1.26 VDC
1.58 kW
0.77 VDC
443 W
0.22 VDC
Resistance - Voltage
orange to yellow
∞
0
1.31 kW
0.64 VDC
3.23 kW
1.40 VDC
5.20 kW
2.46 VDC
7.10 kW
3.42 VDC
8.00 kW
3.88 VDC
9.34 kW
4.63 VDC
©2012 Viking Preferred Service