Troubleshooting - Planet Networking & Communication igs-801m User Manual

Industrial 8-port 10/100/1000mbps managed ethernet switch
Table of Contents

Advertisement

This chapter contains information to help you solve your issue. If the Industrial Managed Switch is not functioning properly,
make sure the Industrial Managed Switch is set up according to instructions in this manual.
■ The Link LED is not lit
Solution:
Check the cable connection and remove duplex mode of the Industrial Managed Switch
■ Some stations cannot talk to other stations located on the other port
Solution:
Please check the VLAN settings, trunk settings, or port enabled / disabled status.
■ Performance is bad
Solution:
Check the full duplex status of the Industrial Managed Switch. If the Industrial Managed Switch is set to full duplex and the
partner is set to half duplex, then the performance will be poor. Please also check the in/out rate of the port.
■ Why the Switch doesn't connect to the network
Solution:
1.
Check the LNK/ACT LED on the Industrial Managed Switch
2.
Try another port on the Industrial Managed Switch
3.
Make sure the cable is installed properly
4.
Make sure the cable is the right type
5.
Turn off the power. After a while, turn on power again
■ 100BASE-TX port link LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to full duplex. Some devices use a physical or software switch to change duplex
modes. Auto-negotiation may not recognize this type of full-duplex setting.
■ Switch does not power up
Solution:
1.
AC power cord is not inserted or faulty
2.
Check whether the AC power cord is inserted correctly
3.
Replace the power cord if the cord is inserted correctly. Check whether the AC power source is working by
connecting a different device in place of the switch.