Wiring The Fault Alarm Contact - Planet Networking & Communication igs-801m User Manual

Industrial 8-port 10/100/1000mbps managed ethernet switch
Table of Contents

Advertisement

2.
Tighten the wire-clamp screws for preventing the wires from loosening.
The wire gauge for the terminal block should be in the range between 12 and 24 AWG.

2.1.5 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the
Industrial Managed Switch
following illustration shows an application example for wiring the fault alarm contacts.
1.
2.
1
2
Power 1
-
+
will detect the fault status of the power failure, or port link failure and then forms an open circuit. The
1
2
Insert the wires into the fault alarm contacts
The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
Alarm relay circuit accepts up to 30V, max. 3A currents.
3
4
5
Fault
Power 2
-
3
4
5
22
User's Manual of IGS-801M