Setting The Terminator - Konica Minolta VIVID 9i/VI Instruction Manual

Non-contact 3d digitizer
Table of Contents

Advertisement

Setting the Terminator

The VIVID 9i has a built-in SCSI terminator. The terminator is required if the VIVID 9i is the last device of
those connected in series to the SCSI interface (i.e., if only one of the SCSI ports on the VIVID 9i is used).
If the terminator is not set correctly, the VIVID 9i or devices connected to the SCSI interface may mal-
function.
M
emo
"ENABLED" has been selected as the default setting before shipment.
N
ote
"DISABLE" must be selected if the VIVID 9i is connected via the SCSI interface but is not the last device of those
connected in series, and "ENABLE" must be selected if it is not connected via the SCSI interface.
[Setting Procedure]
1
Press
.
The MENU view will appear.
2
Press
to locate the arrow cursor to "SC-
SI SETTINGS".
SELECT
3
Press
(or
ENTER
The SCSI SETTINGS view will appear.
4
Press
to locate the arrow cursor to
"TERMINATE".
SELECT
5
Press
(or
ENTER
The currently selected option (ENABLED or DISA-
BLED) will turn to pink.
6
Press
to select "ENABLED" or "DISA-
BLED".
<Settings>
• ENABLED: Select this option if the terminator is to be
used.
• DISABLED: Select this option if the terminator is not to
be used.
).
).
Connecting the VIVID 9i to a Computer
STANDARD
3 HQ ON
NF ON
COLOR OFF
W.B.
DEFAULT
SCSI
5
ENABLED
WHITE BALANCE
INITIAL MODE
INITIAL CONDITION
SCSI SETTINGS
INFO
SCSI SETTINGS
SCSI ID
5
TERMINATE
ENABLED
SCSI SETTINGS
SCSI ID
5
TERMINATE
ENABLED
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vivid 9i

Table of Contents