Request Sense - 03H - SanDisk CompactFlash Product Manual

Hide thumbs Also See for CompactFlash:
Table of Contents

Advertisement

6.1.15

Request Sense - 03H

Bit ->
7
Command (7)
C/D/H (6)
1
Cyl High (5)
Cyl Low (4)
Sec Num (3)
Sec Cnt (2)
Feature (1)
This command requests an extended error code
after a command ends with an error. Table 6-4
defines the valid extended error codes for the
CompactFlash Memory Card Series product. The
Table 6-4 Extended Error Codes
Extended Error Code
00h
01h
09h
20h
21h
2Fh
35h, 36h
11h
18h
05h, 30-34h, 37h, 3Eh
10h, 14h
3Ah
1Fh
0Ch, 38H, 3Bh, 3Ch, 3Fh
03h
SanDisk CompactFlash Memory Card Product Manual © 1998 SANDISK CORPORATION
CompactFlash Memory Card Product Manual
6
5
4
03H
X
1
Drive
extended error code is returned to the host in the
Error Register. This command must be the next
command issued to the CompactFlash Card
following the command which returned an error.
Description
No Error Detected
Self Test OK (No Error)
Miscellaneous Error
Invalid Command
Invalid Address (Requested Head or Sector Invalid)
Address Overflow (Address Too Large)
Supply or generated Voltage Out of Tolerance
Uncorrectable ECC Error
Corrected ECC Error
Self Test or Diagnostic Failed
ID Not Found
Spare Sectors Exhausted
Data Transfer Error / Aborted Command
Corrupted Media Format
Write / Erase Failed
3
2
X
X
X
X
X
X
1
0
69