Request Sense - 03H - SanDisk SDP3B Product Manual

Flashdisk
Table of Contents

Advertisement

6.1.15

Request Sense - 03H

Bit ->
7
Command (7)
C/D/H (6)
1
Cyl High (5)
Cyl Low (4)
Sec Num (3)
Sec Cnt (2)
Feature (1)
This command requests an extended error code
after a command ends with an error. Table 6-4
defines the valid extended error codes for the
SDP3B FlashDisk. The extended error code is
Table 6-4 Extended Error Codes
Extended Error Code
00h
01h
09h
20h
21h
2Fh
35h, 36h
11h
18h
05h, 30-34h, 37h, 3Eh
10h, 14h
3Ah
1Fh
0Ch, 38H, 3Bh, 3Ch, 3Fh
03h
SanDisk SDP3B FlashDisk Product Manual © 1998 SANDISK CORPORATION
6
5
4
03H
X
1
Drive
returned to the host in the Error Register. This
command must be the next command issued to the
SDP3B FlashDisk following the command which
returned an error.
Description
No Error Detected
Self Test OK (No Error)
Miscellaneous Error
Invalid Command
Invalid Address (Requested Head or Sector Invalid)
Address Overflow (Address Too Large)
Supply or generated Voltage Out of Tolerance
Uncorrectable ECC Error
Corrected ECC Error
Self Test or Diagnostic Failed
Spare Sectors Exhausted
Data Transfer Error / Aborted Command
Corrupted Media Format
Write / Erase Failed
SDP3B FlashDisk Product Manual
3
2
X
X
X
X
X
X
ID Not Found
1
0
69

Advertisement

Table of Contents
loading

Table of Contents