ENTERING OR CHANGING YOUR (DEFAULT) ID CODE:
Press d
Press d
Press b & c 12) Press b and c buttons to enter your new "ID Code" number.
Press d
FULL SECURITY LEVEL SUBMENU:
Press d
Press b
Press d
SETPOINT/ID SECURITY LEVEL SUBMENU:
Press d
Press b
Press d
Enter ID menu (Repeat steps from 1 to 3).
10) Display advances to CH.ID Change ID Code Submenu.
11) Display shows 0000 message with flashing 1
If you want to change your default "ID Code" you can do it now,
otherwise press a and menu will skip to FULL Full Security
Submenu.
13) Display shows STRD stored message momentarily and then
advances to the FULL Full Security Submenu.
14) Display flashes ENBL Enable or DSBL Disable.
15) Scroll through the available selections: "Enable" or "Disable".
16) Display shows STRD stored message momentarily and then
advances to SP.ID Setpoint/ID Submenu.
If "Full" Security Level is "Enabled" and the user attempts to
enter the Main Menu, they will be prompted for an ID Code. The
ID Code should be correct to enter the instrument Menu item.
This Security Level can be functional only if FULL Security
Level is Disabled.
17) Display flashes ENBL Enable or DSBL Disable.
18) Scroll through the available selections: "Enable" or "Disable".
19) Display shows STRD stored message momentarily and then
advances to COMM Communication Submenu.
If "Setpoint/ID" Security Level is "Enabled" and the user
attempts to advance into the CNFG Configuration Menu, he will
be prompted for ID Code number. The ID Code should be
correct to proceed into the Configuration Menu, otherwise
display will show an Error and skip to the Run Mode.
If "Full" and "Setpoint/ID" Security Levels are "Disabled", the
ID code will be "Disabled" and user will not be asked for ID
Code to enter the Menu items ("ID" Submenu will not show up in
"ID/Setpoint" Menu).
48