Section 6
Generator
6-1.
GENERAL
This chapter
covers disassembly,
inspection,
and testing of
the
generator
components.
See Figures
6-l
and 6-2 for
parts identification.
grounded.
Never touch electrical
leadi or appliances
with
wet hands,
when
standing
in water,
or on wet ground
as
the chance
of electrocution
is especially
prevalent
under
such conditions.
6-2.
TROUBLESHOOTING
6-3.
GENERATOR
DISASSEMBLY
Refer to Table 4-2 to troubleshoot
the generator.
Follow
the disassembly
procedure
in Section 6-3 as far as necessary
to inspect a component,
then start reassembly procedure
in
Section 6-12 at the point
the component
is replaced, When
a
fuse
must be replaced,
always
inspect the related
com-
ponents
and wiring
to locate the cause. Refer to the wiring
diagrams in the back of the manual,
A
WARNING
HIGH
VOLTAGE!
Remember
that the function
of a gen-
erator
set is to produce
electricity
and
that
wherever
electricity
is present,
there
is the
potential
danger
of
electrocution.
Take the same precautions
with electrical
appliances
in your coach
that you would
observe
in your
home.
Keep away from electrical
circuits
and wiring
while
the set is running
and have electrical
service
performed
only
by
qualified
electricians.
Make
sure
unqualified
persons,
especially
children,
cannot
gain access to your
set-keep
the
compartment
door
locked
or securely
latched
at all times.
Be sure that generator
is properly
NOTE
Tag leads to ease re-installation.
Scratch align-
ing
marks
on parts
before
removing
to
aid
reassembly.
7. Disconnect
battery
of generator
set, negative
lead first.
2. Disconnect
the generator
ground
strap at the tray
(Fig-
gure 6-3 or 6-4). On the 3.5kW and 4.5kW (single), remove
the battery
positive
lead from
the generator
positive
stud
and remove stud remove stud from the generator
mounting.
3. Remove
the center
panel
(4.5, 5.5, 7, 7.5kW),
see Fig-
ure 6-5; or remove the end panel (3.5kW),
see Figure 6-6.
4. Remove the plug from the voltage
sensing
relay
Figure
6-7). The relay can now be removed.
'j 12b
1. End Bracket
7. Panel, Center
12b. Voltage
Regulator
(7.5KW)
18. Ball Bearing
2. Stator
8. Circuit
Breaker(s)
13. Voltage Sensing Relay (VSR)
19. Washer
3. Rotor
9. Junction
Panel
14. Thru Bolt
20. Tolerance
Ring
4. Adapter
IO. Generator
Fan
15. Over Bolt
21.
Brush
5. Guard, Fan
11. Bearing Cap
16. End Bracket
22.
Brush Holder
6. Junction
Panel
12a. Voltage
Regulator
(3.5kW-7kW)
17. Slip Ring
Figure 6-l.
Generator, Cross Sectional View
6-1