Kohler l654 Service Manual page 19

Rv generator
Hide thumbs Also See for l654:
Table of Contents

Advertisement

I2 VOLT
3CRT
La?-
FUEL
'PUMP
.
I
TRANSFORMER
Y
r
CEN::
ATOR
i
t
L2
LI
LO
"EARLIER
MODELS
ONLY
241753
Figure 5-7. Sequence of Operation
Schematic 7.5kW
1. Pressing the start-stop
switch
to the start position
ener-
gizes both
the cranking
contactor
"C"
and the 2CR relay.
(Diode
REI will prevent
this from
happening
if the battery
is connected
in reverse.)
5-4
2. Energizing
the
2CR
relay
will
allow
current
to flow
through
the 10 Amp
in-line fuse to the ignition
coil, choke
heater,
carburetor
shut-down
solenoid
and
electric
fuel
pump (if equipped).
3. Energizing
cranking
contactor
"C"
will allow current
to
flow
to the starter
motor
and crank
the engine. The car-
buretor
choke
solenoid
will
also be energized
and current
can flow through
the normally
closed 4CR contacts
to the
"B"
terminal
of the
aenerator
voltage
regulator
for
the
initial voltage build-up.
4. When the engine
starts and the generator
is producing
AC output,
the 4CR relay (mounted
in the generator
end
bracket)
will energize.
5. The normally
CLOSED
contacts
in the V.B.U.
(voltage
. .
bui,ld-up)
circuit
will then open and disconnect
the battery
supply from the generator
voltage regulator.
6. The normally
OPEN 4CR contacts
will close and allow
the 3CR relay to become energized.
All the 3CR contacts
will
then
change
positions,
the
normally
open
contacts
will
close
and the
normally
closed
contacts
will
open.
7. The
normally
closed
3CR
contacts
in series with
the
"C"
cranking
contactor
will
open
deenergizing
the
"C"
contactor.
This offers
protection
from engaging the starter
motor while the unit is operating.
8. The 3CR contacts
in series with the 2CR relay coil will
close,
maintaining
current
flow
to
the
2CR
relay
coil.
The 2CR relay controls
current
flow to the engine ignition
circuit.
9. The
now
closed
3CR
contacts
in series with
the ICR
relay coil and engine safety cutouts
will allow the ICR relay
to
become
energized
if the safety
cutout
contacts
close.
The ICR relay also energizes when the start-stop
switch
is
placed in the stop position.
10. Energizing
the ICR relay,
either
by the engine safety
cutouts
or by placing the start-stop
switch to the stop posi-
tion will disrupt
current
flow
to the 2CR relay coil and in
turn
prevent
current
flow
to the ignition
circuit
when the
2CR contacts
in this circuit
open.
5-3.
FUSES
A
WARNING
UNIT STARTS
WITHOUT
NOTICE!
To prevent
accidental
starting
on units with a remote
start/stop
switch,
always
disconnect
battery
(remove
negative
lead first and recon-
nect it last) to disable
generator
set before working
on any
equipment
connected
to generator.
There is one IO Amp
fuse
inside the controller
(Figure 5-l).
This
fuse
protects
the controller
against
damage
in the
event
a short
develops
in the engine wiring.
If this fuse
"blows"
the set will
stop.
If the set has stopped
due to
causes other
than lack of fuel, engine malfunction,
or low
oil pressure,
remove the cover of the controller
and check
the fuse. If blown,
replace the fuse then attempt
to restart
the
generator
set. If the set will
not start,
or if the fuse
blows again, locate and correct the cause.