Section
7
Choke, Shutdown Control and Governor
7-1. CHOKE
TESTING
AND
ADJUSTMENTS
(3.5kW,
4.5kW SINGLE)
A
WARNING
BACKFIRE!
A sudden
backfire
can cause serious
burns.
Keep hands and face away from the carburetor
when the
air cleaner
is removed.
7-1.1
General.
When the engine start switch
is activated,
battery
current
activates
the rotary
solenoid
in the electric
choke unit
(Figure
7-l).
The choke lever pushes the choke
plate into the full choke position.
The solenoid
deenergizes
immediately
after the switch is released from the start posi-
tion.
When the solenoid
deenergizes,
the choke plate opens
to a position
determined
by a thermostatic
spring and the
ambient
temperature.
As the engine warms and less choking
is needed,
the thermistor
circuit
allows the choke
plate to
gradually
move to full open position.
A
WARNING
UNINTENTIONAL
STARTING!
To
prevent
accidental
starting
when
checking
choke
operation,
remove
spark
plug lead(s)
at spark plug(s).
A
WARNING
FLASH FIRE! Asudden
flash fire can cause serious
burns.
To avoid
the possibility
of a flash fire, do not smoke
or
permit
flame or spark to occur
near carburetor,
fuel line,
fuel filter, fuel pump,
or other potential
sources
of spilled
fuel or fuel vapors.
7-1.2.
Inspection.
1. Disconnect
the
high tension
lead from
the spark plug
so
the engine will not start.
2. Remove the air cleaner cover, element and base plate.
3. Push the start-stop
switch on the controller
to the start
position
and hold for five seconds. The choke plate should
CHOKE
SHAFT
/
ONE LEAD TO
STARTER
RELAY
THE OTHER
LEAD
TO CONTROLLER
HEATER
(THERMISTOR)
TERMINAL
LOCKWASHER
IDLE FUEL
ADJUSTMENT
SOLENOID
TABS
AUTOMATIC
ELECTRI-CHOKE
UNIT
I
LEVER
l/2 TURN TENSION
SPRING
Figure 7-1. Choke and Carburetor