Governor (7.5Kw) - Kohler l654 Service Manual

Rv generator
Hide thumbs Also See for l654:
Table of Contents

Advertisement

Figure 7-11.
Governor Sensitivity Adjustment
(4.5kW Twin)
1. To
increase
speed,
loosen
the
inside
speed adjusting
nut
(Figure
7-12) and tighten
the outside
nut to draw the
eyebolt
closer to the
bracket
which
is mounted
on the
governor.
This will pull the throttle
open.
2. To decrease speed, ~Ioosen the outside
nut and tighten
the inside nut tovforce the eyebolt
away from the bracket.
.3. When speed is correct,
tighten
the nut that was loosened
to lock the eyebolt
at the new setting.
SPEED ADJUSTING
EYE BOLT
UPPER NUT
CRANKCASE
BREATHER
INCREASE
SPEED
\
DE NUT
THROTTLE
/I-VI
LINKAGE
~-??5lll
SENSITIVITY
BRACKET
GOVERNOR'
GOVERNOR
SPRING
INCREASE
SENSITIWITY
Figure 7-12.
Governor Components
and Adjustments
(5.5kW, 7kW)
7-8.3.
Sensitivity
Adjustment.
If the governor
is too sensi-
tive, speed surging
will
occur
with
change in load.
If the
governor
is not sensitive
enough,
a big drop in speed will
occur
when normal load is applied.
1. To make the governor
moresensitive,
loosen the upper
nut and tighten
the lower nut to force the eyebolt
down-
ward.
2. To
make the governor
less sensitive,
loosen the lower
nut and tighten
the upper nut to draw the eyebolt
upward.
3.
Retighten
the nut that was loosened to lock the eyebolt
at the new setting.
7-8.4.
Anti-Dieseling
Control
Adjustment.
Used with
car-
buretor
assembly
48 053 29. See Figure
7-13 for dimen-
sions.
1. With
anti-dieseling
control
dimensions
correct,
hold
governor
arm in fully
closed position.
See Figure 7-13 (bot-
tom view).
2. With solenoid
plunger fully
in solenoid,
adjust solenoid
coil
so chain
is taut.
Tighten
solenoid
hold-down
clamp.
3. With
governor
arm fully
closed, adjust carburetor
idle
stop screw one-turn
in after screw makes contact
with stop
spring.
NOTE
Solenoid
is energized
only
when stop button
is
held in stop position.
7-9. GOVERNOR
(7.5kW)
7-9.1
General.
This
model
is equipped
with
a constant
speed type
governor.
The governor
drive gear is driven
by
the cam gear. Lubrication
is provided
through
an external
oil line which connects to the engine lubrication
system.
79.2.
Speed Adjustment.
The throttle
shaft
is fixed
at a
definite
length
to
establish
a load speed of
1800
RPM
(1500
RPM,
50 Hz models).
Any
variation
in speed fre-
quency changes the output
of the generator.
For this reason
only
slight
readjustment
of speed is possible.
Proceed as
follows:
NOTE
Due
to
variances
in generator
output
wave-
shape, not all pointer
type frequency
meters are
compatible.
1. To increase speed, loosen locking
nut on speed adjusting
screw (Figure 7-14), and turn screw in clockwise
direction.
7-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents