CONDITION
1. Engine will not crank.
POSSIBLE
CAUSE/CORRECTION
(SECTION)
1. Battery
cable connections
reversed. (Must be negative ground.)
2. 10 amp fuse in controller
blown
(5-3).
3. Defective
start switch or "C"
relay (5-2).
4. Open circuit
in wiring
harness or connector.
5. Faulty
starter motor.
6. Open circuit
in REI diode (5-4).
7. Normally
closed 3CR contacts,
open (5-5).
8. Busted or loose ground strap.
2. Engine cranks but will not start.
1. Choke
not operating
or out of adjustment
(7-1, 7-2).
2. Check
fuel supply
to carburetor.
3. Faulty
fuel shut-down
control
(7-3).
4. Faulty
fuel pump.
5. Dirty or stuck
ignition
points.
6. Faulty
condenser.
7. Faulty
spark plug.
3. Engine starts, then stops when
switch is closed.
8. 2CR relay not functioning.
Must have battery
voltage
on positive
connection
of ignition
coil (5-5).
9. Fuel mixture.
Replace.
1. No AC generator
output.
2. Faulty
3CR interlock
relay (5-5).
3. Faulty
4CR voltage sensing relay (5-5).
4. Faulty
exciter
voltage regulator
(6-7).
4. No AC output.
1. Circuit
breakers
in the off position
(2-3).
2. Generator
brushes not making contact
on slip rings (6-5).
3. Faulty
build-up
circuit.
Battery
voltage must be present at terminal
"B"
of regulator
during cranking
(6-7).
4. Open connection
in wiring
harness or plug connector
(5-2).
5. Faulty
exciter
voltage regulator
(6-7).
6. Circuit
protector
tripping
due to overload,
reduce load.
5. Low output
or excessive drop in
voltage (below
1 IO volts).
1. Generator
set overloaded.
2. Engine
rpm set too low (7-5 thru 7-9).
3. Faulty
exciter
voltage
regulator
(6-7).
4. Poor stator
coil connections,
use a clamp-on
ammeter
and check
each connection.
.
6. High AC voltage (above 125 volts AC).
1. Faulty
exciter
voltage regulator.
2. Stator
reconnected
improperly.
7. Engine shuts down for no apparent
reason.
1. Generator
set overheated
-
improper
installation.
Refer to RV
installation
manual
or 75kW
Owner's
Manual.
2. No fuel.
3. Oil level or oil pressure
system
failure.
4. Faulty
shutdown
solenoid.
8. Unit will not operate with remote
switch - OK at controller.
I.
Incorrect
wiring
of remote switch to remote
plug assembly.
Center
pole of remote switch
must connect
to terminal
4 of remote harness
plug, Figure 5-2.
2. Open connection
in wiring.
Table 4-2. Troubleshooting
Generator