Kohler l654 Service Manual page 25

Rv generator
Hide thumbs Also See for l654:
Table of Contents

Advertisement

Figure 6-13.
Over Bolt Removal (Two Shown)
11.
Lift the brushes
by the leads and lock
in this position
by inserting
a retainer
wire as shown
in Figure
6-12.
12.
Remove
the end
bracket
by removing
four
long over
bolts.
See Figure
6-13.
13.
Disconnect
the stator
leads from
the regulator.
NOTE
The voltage
regulators
on 4.5,
5.5, 7 and 7.5kW
generator
sets are located
inside the end bracket.
On the
3.5kW,
the voltage
regulator
is located
outside
the end
bracket.
See Figures
6-14
and
6-15.
Terminal
connections
and testing
will be
the same for all.
Figure 6-14.
Exciter / Voltage Regulator
Figure 6-15.
Exciter / Voltage Regulator (3.5KW)
14.
The stator
(Figure
6-16)
can be tested
at this time
(Sec-
tion 6-8).
Remove
the stator
by guiding
it to the rear,
15.1
l
Four-Pole
Removal
(4.5,
5.5,7,7.5kW).
Remove
thru
bolt
and detach
washers.
Re-insert
thru
bolt
leaving
a l/8
6-4