Setting Up PROFINET Communications

Setting Network Settings in the Sensor
Set the IP address of the Sensor according to the network where the external devices, such as PLCs, are
connected.
(Setup Mode) − [Sensor settings] − [Network] − [Ethernet] − [IP address setting]
1
Press [Fixed].
2
Set the IP address and subnet mask according to the network where the external devices are con-
nected.
Important
To use PROFINET communications, do not automatically assign an IP address to the Sensor. Set a specific IP
address and do not change it.
Initial Settings for PROFINET Communications
(Setup Mode) − [Sensor settings] − [Data output] − [Fieldbus data output]
1
Press [Communication type].
2
Press [PROFINET].
3
Set the PROFINET communications parameters as
described in the following table.
FQ2-S/CH User's Manual
for Communications Settings
[Output handshake] Set to [Yes]
[Output handshake] Set to [No]
Outputting Data and Controlling Operation through PROFINET
149