Binary Data File Load And Save Commands - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Type of command
Save setting data com-
mands

Binary Data File Load and Save Commands

These commands allow various types of sensor data to be saved in binary data format.
Use these commands when you want to directly control scene data and system data from the external device
side (user side) rather than the sensor side. For this purpose, a send/receive program is created on the user
side, and the commands are incorporated into the program. Be sure to have a good understanding of binary
data and the send/receive system before considering use of these commands.
These commands can also be used in no-protocol TCP communication. The commands cannot be used in no-
protocol UDP communication or no-protocol RS-232C communication.
How to Execute Binary Data File Load/Save Commands
Two command types are available for these commands: check commands and run commands.
To execute one operation, control must be performed using a combination of the two types of commands.
• Check command: Sends notification of the size of the binary data to be saved or loaded.
• Run command: Executes saving or loading of binary data.
Important
If the check command is not executed, the run command that executes saving/loading of binary data will not be pro-
cessed properly.
Using the Commands
Create the command send/receive program so that the check command is always executed before the run
command. Command execution is accomplished by the user-created send/receive program that incorporates
the check commands and run commands in the above order.
Saving and loading of binary data using check commands and run commands is as shown below.
188
Control and Output in No-Protocol (TCP) / No-Protocol (UDP)
Command
Abbreviation
LASTIMAGE-
SAVE
LIS
LOGDATASAVE
LDS
TOTAL-
TDS
DATASAVE
Function
Saves the latest input image to the
SD card inserted in the Touch Finder
as ifz data.
Saves measurement data saved in
the Sensor's memory by the logging
function to the SD card inserted in the
Touch Finder as csv data.
Saves statistical data saved in the
Sensor's memory by the logging func-
tion to the SD card inserted in the
Touch Finder as csv data.
for Communications Settings
Reference
p.366
p.367
p.368
FQ2-S/CH User's Manual