High or low level signal that was configured on the software is output.
Setting Procedure
Selects Line N (N: any number from 0, 1 or 2)
1) Sets the User Output N (N is Line number) as Line Source
2) Selects User Output N (N is same as selected Line number on User Output) on User Output Selector
3) Sets the value (True: High level, False: Low level) on User Output Value
Monitor the status on output port.
Monitor the output voltage level High (Line Status: true) or Low (Line Status: false) through the software.
Some selectable functions can be modified in order to add to the duration or pulse width on Line Source.
The configurable parameters are shown in the chart below.
Please refer to Line Source for the applicable functions of Parameters.
GenICamParameters
TriggerOutDelay
TriggerOutOnTime
StrobeOutDelay
StrobeOutOnTime
8.3

Hardware Reset

The hardware reset can be done by CAM_RESET port.
Sets On (Default: Off) at Line Device Reset Mode, and apply the Low voltage in 5 seconds on CAM_RESET port then
camera rest.
STC-MBS312U3V / STC-MCS312U3V / STC-MBS500U3V / STC-MCS500U3V
Product Specifications and Use's Guide
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *aegis-g2@aegiselect.com *http://www.aegiselect.com
Integer Type
Trigger Out Delay Time
Range: 0 to 262,143 μseconds, Default: 0 μsecond
Integer Type
Trigger Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds
Integer Type
Strobe Out Delay Time
Range: 0 to 262,143 μseconds, Default: 30 μseconds
Integer Type
Strobe Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds
No.16S024-02