User Output; Linestatus; Output Signal Duration Setting And Pulse Width Setting - Omron CoaXPress STC-LBGP251BCXP124 Product Specifications And User's Manual

Monochrome / color cmos camera
Table of Contents

Advertisement

10.2.2

User Output

High or low level signal that was configured on software is output.
Setting Procedure
Selects LineN (N: any number from 0, 1 or 2)
1) Sets the UserOutputN (N is Line number) as LineSource
2) Selects UserOutputN (N is same as selected Line number on UserOutput) on UserOutputSelector
3) Sets the value (True: High level, False: Low level) on UserOutputValue
10.2.3

LineStatus

Monitor the status on output port.
Monitor the output voltage level High (LineStatus: true) or Low (LineStatus: false) through software.
10.2.4

Output signal duration setting and Pulse width setting

Some selectable functions can be modified in order to add to duration or pulse width on Line Source.
The configurable parameters are shown in chart below.
Please refer to LineSource for applicable functions of parameters.
GenICam Parameters
TriggerOutDelay
TriggerOutOnTime
StrobeOutDelay
StrobeOutOnTime
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User's Guide
IInteger Type
Trigger Out Delay Time
Range: 0 to 262,143 μseconds, Default: 0 μsecond
IInteger Type
Trigger Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds
IInteger Type
Strobe Out Delay Time
Range: 0 to 262,143 μseconds, Default: 30 μseconds
IInteger Type
Strobe Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds
No.20S062-00