Omron FQ2-S/CH Series User Manual page 254

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Set Communication Input Status
This command sets the input status (allowed/prohibited) of the communications port for the specified
communications protocol.
Communications protocols with the input status set to prohibited will no longer receive communications after
being set as such.
However, for inputs related to hardware (parallel STEP signal and DSA signal), this setting is not applicable.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
+4
+5
+6
+7
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
*
The communications protocol types are defined by the following numbers.
Communica-
tions protocol
No.
0
No protocol (Ethernet)
1
No protocol (RS-232C)
2
Parallel I/O
3
Fieldbus
4
Reserved
5
PLC link
252
Command Control
Bits
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bits
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0011
0000
0000
0000
0000
0000
0000
Communications type
No-protocol (UDP)
No-protocol (TCP)
EtherNet/IP
PROFINET
PLC Link (SYSMAC)
PLC Link (MELSEC)
Description
0 to 3
0000
Command code
0000
0000
Communications protocol type to be set*
0: No protocol (TCP, UDP, FINS)
0000
1: No protocol (RS-232C)
2: Parallel I/O
3: Fieldbus
5: PLC link
0000
Communications protocol status to be set
0: Input prohibited status
0000
1: Input allowed status
Description
0 to 3
0000
Command code
The command code for which the response
0000
applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
Results in an error when specified.
Remarks
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading

Table of Contents